Viewing Study NCT01603706


Ignite Creation Date: 2025-12-26 @ 5:24 PM
Ignite Modification Date: 2025-12-26 @ 5:24 PM
Study NCT ID: NCT01603706
Status: COMPLETED
Last Update Posted: 2017-10-19
First Post: 2012-05-14
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Radial Strain ECHO-Guided Implantation of Cardiac Resynchronization Therapy
Sponsor: Sheba Medical Center
Organization:

Study Overview

Official Title: Radial Strain Imaging-Guided Lead Placement for Improving Response to Cardiac Resynchronization Therapy in Patients With Ischemic Cardiomyopathy: A Randomized Clinical Trial
Status: COMPLETED
Status Verified Date: 2017-10
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: RAISE-CRT
Brief Summary: The purpose of this study is to evaluate the use of radial strain imaging using speckle tracking analysis to predict the response to CRT in patients with ischemic cardiomyopathy (ICMP) with NYHA functional class 2-4 heart failure and a standard guideline-based CRT indication. Thus assessing the value of lead localization determined by radial strain imaging in a prospective, randomized manner.
Detailed Description: In this study we propose to evaluate the utility of radial strain imaging using speckle tracking to predict the response to CRT in patients with ischemic cardiomyopathy (ICMP) with NYHA functional class 2-4 heart failure and a standard guideline-based CRT indication, and to determine the value of lead localization determined by radial strain imaging in a prospective, randomized manner. We will compare two randomized groups of CRT recipients implanted with CRT-D systems. In the control group, implantation will be performed in the usual manner and the lead will be placed at the discretion of the implanting physician, preferably at posterolateral LV sites . In the study group, leads will be placed in areas of latest contraction that lack significant scar, as determined by speckle tracking imaging. The primary outcome measure for comparison between the 2 groups will be echocardiographic response (as assessed by percent reduction in left ventricular end systolic volumes) at 6 months post-implantation. In addition, clinical response parameters will also be measured as secondary end points.

We hypothesize that 1) patients showing greater dyssynchrony and/or discoordination index with speckle tracking will derive a significantly greater response to cardiac resynchronization therapy; and 2) patients allocated to the image-guided LV lead placement group will derive a significantly greater response to CRT than patients in the non- guided implantation (control) group.

If radial strain imaging proves useful for improving the CRT response rate and identification of patients likely to respond, it will have important clinical and economic implications by improving individual outcomes and more effective utilization of constrained health care resources. Furthermore, if echo-guided lead implantation proves to be effective in reducing the relatively large non-response rate to cardiac resynchronization therapy, it will likely result in increased device utilization among eligible heart failure patients.

Specific Aims Aim #1: To show that in patients with ischemic cardiomyopathy, implantation of a CRT LV lead guided by radial strain imaging results in a significantly greater echocardiographic and clinical response to cardiac resynchronization therapy compared with conventional implantation techniques.

Aim #2: To show that speckle tracking strain data can be used to identify the degree of echocardiographic response to CRT, using both dyssynchrony (time to peak strain ) and discoordination indices.

Aim #3:

The Paieon substudy will comprise 40 patients enrolled at 3 centers, for whom additional information mechanical dyssynchrony, using the Paieon CardioGuide motion map, will be collected during device implantation as detailed below The primary aim of the study is to relate data of mechanical dyssynchrony obtained from angiography through the Paieon CardioGuide motion map to dyssynchrony data obtained from the echocardiogram.

The dyssynchrony data will not be available to the treating physicians and will not be used to direct the LV lead location.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: