Viewing Study NCT03405506


Ignite Creation Date: 2025-12-26 @ 1:19 PM
Ignite Modification Date: 2025-12-31 @ 12:32 PM
Study NCT ID: NCT03405506
Status: COMPLETED
Last Update Posted: 2025-06-03
First Post: 2018-01-12
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Functional Diagnostic Accuracy of Quantitative Flow Ratio in Tandem Lesions and Virtual Stenting
Sponsor: Pulse Medical Imaging Technology (Shanghai) Co., Ltd
Organization:

Study Overview

Official Title: Functional Diagnostic Accuracy of Quantitative Flow Ratio in Tandem Lesions and Virtual Stenting
Status: COMPLETED
Status Verified Date: 2025-05
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: FORTRESS
Brief Summary: Quantitative Flow Ratio (QFR) is a novel method for evaluating the functional significance of coronary stenosis. Virtual stent implantation technique combined with QFR was recently developed to predict the functional significance of coronary stenosis as if the stenosis was revascularized.

The purpose of this study is to evaluate the diagnostic accuracy of QFR in in tandem lesions with fractional flow reserve (FFR) as the reference standard. The secondary purpose is to evaluate the diagnostic accuracy of QFR-based virtual stent technique in predicting the FFR values after revascularizing the culprit lesion.
Detailed Description: QFR is a novel method for evaluating the functional significance of coronary stenosis by calculation of the pressure drop in the vessel. 3D coronary models can be reconstructed based on two angiographic projections to obtain the geometric parameters, including vascular diameter or cross-sectional area. According to the lesion stenosis, vessel curvature, conical geometry and reference lumen characteristics, pressure drop can be calculated in real time based on its relationship with blood flow. There is no need for pressure wire and adenosine / ATP induced maximum hyperemia compared with FFR.

The FAVOR Pilot Study and FAVOR II China Study showed promising results for diagnostic accuracy in consecutive patients. However, the diagnostic accuracy of QFR in specific tandem lesions needs further investigation. Furthermore, using the virtual stent technology to accurately assess the culprit lesion and choose the optimal treatment is significant in precisely guiding PCI surgery.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: