Viewing Study NCT02042716


Ignite Creation Date: 2025-12-26 @ 11:46 AM
Ignite Modification Date: 2026-02-25 @ 6:59 PM
Study NCT ID: NCT02042716
Status: COMPLETED
Last Update Posted: 2019-04-17
First Post: 2013-07-26
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Added Value of Supersonic Shear Imaging in the Diagnosis of White Matter Damage in Preterm Infants
Sponsor: Assistance Publique - Hôpitaux de Paris
Organization:

Study Overview

Official Title: Added Value of Supersonic Shear Imaging in the Diagnosis of White Matter Damage in Preterm Infants
Status: COMPLETED
Status Verified Date: 2018-02
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: BELUGA
Brief Summary: Preterm birth and perinatal events related can interrupt microscopic maturation of the developing white matter leading to diffuse injury and subsequent neurocognitive impairments. Brain maturation can be studied using diffusion tensor imaging but is difficult to assess early after birth, repeatedly and at the bedside. Supersonic Shear wave Imaging (SSI) could be of interest in this clinical setting. This technique, already investigated in adults (breast, thyroid or liver fibrosis staging), has not been yet evaluated in neonates.

Objective:

To describe the feasibility and reproducibility of quantitative elasticity mapping in preterm infants and to correlate to gestational age.

Methods:

SSI is a quantitative stiffness imaging technique based on the combination of a remote palpation induced into tissues by the radiation force a focused ultrasonic beam and an ultrafast ultrasound imaging sequence. Such ultrafast frame rates permit to track in real time the displacements induced by the propagation of the resulting shear waves. For each pixel, the shear wave speed can be estimated locally and enables quantitative mapping of the local shear elasticity (characterizing the stiffness in kPa). In this study, we will use a new generation of ultrafast ultrasound scanners (Aixplorer®, Supersonic Imagine, Aix en Provence, France) with a linear L10-2 probe (256 elements, 6 MHz) in neonates born between 25 and 40 weeks' gestation (n=100). Three separate acquisitions will be obtained for each area of interest both on right and left sides and stiffness was measured using a unique ROI of 2.5 cm².
Detailed Description: White matter damage occurs in 20% of preterm infants in industrialized countries. These lesions are difficult to evaluate by standard ultrasound. The quantitative elastography is a new medical imaging technique and potentially a diagnostic tool in brain lesions in preterm infants. Shear wave Imaging (SSI) could be of interest in this clinical setting. This technique, already investigated in adults (breast, thyroid or liver fibrosis staging), has not been yet evaluated in neonates.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?:

Secondary ID Infos

Secondary ID Type Domain Link View
ID RCB : 2012-A01530-43 OTHER ID RCB View