Viewing Study NCT05616156


Ignite Creation Date: 2025-12-24 @ 11:17 PM
Ignite Modification Date: 2026-01-02 @ 2:00 AM
Study NCT ID: NCT05616156
Status: UNKNOWN
Last Update Posted: 2022-11-15
First Post: 2022-11-08
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: The Cre8™ BTK Post Market Clinical Follow-up Study
Sponsor: CID S.p.A.
Organization:

Study Overview

Official Title: Sirolimus Drug-eluting Stent for the Treatment of Infrapopliteal Peripheral Artery Disease: Evaluation of Safety and Performance in Everyday Clinical Practice. The Cre8™ BTK Post Market Clinical Follow-up Study.
Status: UNKNOWN
Status Verified Date: 2022-11
Last Known Status: NOT_YET_RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Cre8™ BTK is a CE marked drug eluting stent, integrally coated with i-Carbofilm, loaded with formulated Sirolimus for the treatment of infrapopliteal peripheral artery disease.

The aim of this post-market retrospective study protocol P32102 is to collect clinical data of patient treated with Cre8™ BTK stent in routine clinical practice.

In order to obtain long-term follow-up data, the data collection will be limited to patients that have been treated with the Cre8™ BTK stent at least 12 months prior to the study start.
Detailed Description: The objective of this post-market observational study is to collect retrospective clinical data on the implantable medical device Cre8™ BTK in an unselected population, in the current clinical practice treated within the intended use. Data will be collected via medical chart review in anonymous form to assess the safety and efficacy of the device.

The Cre8™ BTK stent is made of cobalt-chromium alloy (L605) and it is coated with iCarbofilm™, a thin carbon film with a high density turbostratic structure substantially identical with that of the pyrolytic carbon used for mechanical cardiac valve discs. Coating the substrate with iCarbofilm™ provides it with the bio- and haemocompatible characteristics of pyrolytic carbon, without affecting the physical and structural properties of the substrate itself. The outer surface of the stent has dedicated grooves, fully coated with iCarbofilm™, for containing the pharmaceutical formulation Amphilimus™, which is composed of the drug sirolimus and a mixture of long-chain fatty acid.

The specific drug dosage is 0.9 μg/mm2 corresponding to a minimum dose of 50 μg on the smaller stent (2.25x8mm) and a maximum dose of 395 μg on the larger stents (4.0x38mm and 3.5x46mm). Two radiopaque platinum markers, positioned at each end of the stent, allow to correctly position it over the lesion to be treated.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: