Viewing Study NCT04434456


Ignite Creation Date: 2025-12-24 @ 11:16 PM
Ignite Modification Date: 2025-12-25 @ 8:55 PM
Study NCT ID: NCT04434456
Status: UNKNOWN
Last Update Posted: 2020-09-02
First Post: 2020-06-08
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Carotid Artery Aneurysm Treatment Using CGuard Divert-And-Heal Strategy
Sponsor: John Paul II Hospital, Krakow
Organization:

Study Overview

Official Title: Prospective Observational Study of CGuard MicroNet Covered Stent System Use as a Flow Diverter in the Endovascular Exclusion of Carotid Artery Aneurysms. (CGuard Divert-and-HEAL C-HEAL)
Status: UNKNOWN
Status Verified Date: 2020-08
Last Known Status: RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: C-HEAL
Brief Summary: Non-randomized, single arm, open label, academic observational study of CGuard MicroNet covered stent system use to achieve endovascular lumen reconstruction in carotid artery aneurysms with indications for treatment (enlarging and/or dissecting / symptomatic).

Jagiellonian University Medical College research project.
Detailed Description: Carotid artery aneurysm (CAA) is a relatively infrequent, but significant clinical condition with numerous diagnostic and therapeutic implications. CAA affects laminal flow in the carotid artery implicating the risk of thrombus formation in the aneurysm cavity, and subsequent ischemic stroke from distal embolization. Another important clinical problem related to the CAA is a possible aneurysm dissection and rupture. Symptomatic CAA and increasing dimensions of CAA institute unquestioned indications for the CAA treatment.

Surgical carotid aneurysm repair bears a significant risk (periprocedural stroke, cranial nerve damage, carotid artery ligation). Therefore endovascular techniques of CAA exclusion were developed. Covered stents, stent-grafts, and combined stenting and aneurysm embolization with coils were applied. However, covered stents were demonstrated to increase the restenosis risk, and other complications such as CAA neck endo-leak.

Newer technique involves the flow diversion by implantation of stent in dense-structured stent (such as Wallstent) or stent-in-stent implantation. In this case a luminary flow dominates over aneurysm filling, which is limited by stent structure. Gradual thrombosis and occlusion of aneurysm cavity and healing of aneurysm follows.This method disadvantage was related to necessity of double stent load and increased restenosis risk (double metal layer).

These issues were addressed only recently by the double layer mesh stents that demonstrate natural flow diverting capabilities. CGuard Stent system is a self-expandable stent covered with PET mesh (MicroNet) that prevents plaque protrusion into the vessel lumen. In addition, in low flow conditions MicroNet can act as the flow diverter. These stents are routinely implanted in elevated risk plaques in high reference centers in Europe.

Several published observations indicate the CGuard stent also demonstrates flow-diverting capabilities, but the systematic observation of such application was not performed.

C-HEAL is a non-randomized, single arm, open label academic observational study of CGuard stent implantation in carotid arteries in patients with symptomatic, dissecting or enlarging carotid artery aneurysm. Procedures are performed according to the center routine, with application of proximal or distal embolic protection device (if feasible), and standard pharmacotherapy according to the current guidelines.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: