Viewing Study NCT00950469


Ignite Creation Date: 2025-12-24 @ 11:02 PM
Ignite Modification Date: 2025-12-28 @ 1:38 AM
Study NCT ID: NCT00950469
Status: COMPLETED
Last Update Posted: 2009-07-31
First Post: 2009-07-30
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: TnThs for Identification Myocardial Infarction
Sponsor: Heidelberg University
Organization:

Study Overview

Official Title: Comparison of the New High Sensitive Cardiac Troponin T With the 4th Generation Troponin-T, Myoglobin, Heart-type Fatty Acid Binding Protein for Early Identification of Myocardial Necrosis in Patients With Suspected Acute Coronary Syndrome
Status: COMPLETED
Status Verified Date: 2009-07
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: OBJECTIVES/BACKGROUND: We sought to determine the early diagnostic value of the new high sensitive cardiac troponin T assay (TnThs) in suspected acute coronary syndrome (ACS) and to compare it with the 4th generation cTnT assay from the same manufacturer, myoglobin and heart-type fatty acid binding protein (h-FABP).

METHODS: The study consisted of 94 patients with chest pain admitted to the chest pain unit with the diagnosis of suspected ACS without ST-Elevation. Patients were divided according to time from onset of symptoms to presentation into an early presenter group (\<4 hours) and a late presenter group (≥4 hours).

A median of 6 samples (range 2-8) were available per patient. The diagnostic performance of TnThs was assessed using ROC analysis and areas under the curve (AUC) of baseline and follow-up results of TnThs, cTnT, myoglobin, and h-FABP were compared using c-statistics.

RESULTS: The TnThs assay allows an excellent prediction of non-ST-segment-elevation myocardial infarction (non-STEMI) at presentation.A follow-up sample improves diagnostic performance in a time dependent manner. The AUC of the TnThs was superior to cTnT at all time points.

CONCLUSIONS: A baseline sample of TnThs allows an earlier prediction of non-STEMI than the less sensitive and precise 4th generation cTnT assay. The excellent performance of TnThs at baseline and follow-up might obviate the need for other early necrosis markers.
Detailed Description: None

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: