Viewing Study NCT05510869


Ignite Creation Date: 2025-12-24 @ 10:47 PM
Ignite Modification Date: 2026-01-01 @ 8:32 AM
Study NCT ID: NCT05510869
Status: COMPLETED
Last Update Posted: 2022-08-22
First Post: 2022-08-18
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Evaluation of the Impact of Corneal Width on Surgically Induced Astigmatism (SIA) and Functional Results After Bimanual 1.4 mm Microincision Cataract Surgery (B-MICS), Coaxial 1.8 mm MICS (C-MICS) and 2.4 mm Small Incision Cataract Surgery (C-SICS).
Sponsor: Medical University of Lodz
Organization:

Study Overview

Official Title: Comparison of Surgically Induced Astigmatism After Microincision Cataract Surgery (B-MICS 1.4 mm and C-MICS 1.8 mm) and C- SICS 2.4 mm
Status: COMPLETED
Status Verified Date: 2022-08
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: MICS
Brief Summary: The aim of the study is to compare functional results and complications of 3 methods of cataract phacoemulsification: bimanual 1.4 mm cataract surgery (B-MICS), coaxial 1.8 mm cataract surgery (C-MICS) and coaxial 2.4 mm small incision cataract surgery.
Detailed Description: Reduction of the width of the corneal incision was one the main changes taking place in cataract surgery in recent years. The common use of foldable intraocular lenses (IOLs) and technological development of phaco machines allowed to reduce clear corneal incision below 3 mm. Term of Microincision Cataract Surgery (MICS) understood as cataract phacoemulsification performed with the incision width below 2 mm was defined by professor Alio in 2003. However, despite various modifications introduced in recent years, phacoemulsification still causes damage of the tissues that results in surgically induced astigmatism.

Two MICS techniques have been developed: bimanual microincision cataract surgery (B-MICS) and coaxial microincision cataract surgery (C-MICS).

In the bimanual technique cataract phacoemulsification can be performed through the main incision 1.4 mm wide due to the usage of sleeveless phaco tip (without irrigation) and irrigation chopper. The advantage of separation the irrigation from aspiration is improvement of liquid dynamics in the anterior chamber. Moreover, due to the usage of the irrigation chopper, in B-MICS it is possible to lower the mean ultrasound energy.

In coaxial technique MICS phacoemulsification is performed through the incision 1.8 mm wide with usage of phaco tip with a silicon irrigation sleeve.

The aim of the study is to compare functional results and complications of 3 methods of cataract phacoemulsification: bimanual 1.4 mm cataract surgery (B-MICS), coaxial 1.8 mm cataract surgery (C-MICS) and coaxial 2.4 mm small incision cataract surgery. Moreover, this study aimed to evaluate the impact of corneal width on best corrected visual acuity (uncorrected and corrected), surgically induced astigmatism, endothelial cell loss, intraocular pressure, anterior segment of the eye and central retinal thickness.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: