Viewing Study NCT03803969


Ignite Creation Date: 2025-12-24 @ 10:47 PM
Ignite Modification Date: 2026-01-02 @ 4:41 AM
Study NCT ID: NCT03803969
Status: COMPLETED
Last Update Posted: 2025-01-14
First Post: 2019-01-10
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: ConfirmRxTM: Posture and Activity
Sponsor: Abbott Medical Devices
Organization:

Study Overview

Official Title: ConfirmRxTM: Effects of Patient Posture and Physical Activity
Status: COMPLETED
Status Verified Date: 2025-01
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Insertable Cardiac Monitor's (ICM's) such as Confirm Rx™ are leadless devices implanted for long-term heart rhythm monitoring in the diagnosis and management of clinical conditions such as recurrent unexplained syncope, cryptogenic stroke, ventricular arrhythmias and monitoring atrial fibrillations (AF) post ablation. There is limited data on variations seen in signal sensing with changes in physical activity and posture. This single arm, non-randomized, open-label, multi-center, clinical investigation of 100 subjects is designed to characterise the safety and performance of Confirm RxTM by assessing quality of signal attained from the device with changes in posture and physical activity at implant and 30days post procedure. The study is also intended to assess gross migrations of the device at 30days post implant.
Detailed Description: Syncope is a condition that has vexed cardiologists worldwide due to its elusive nature. Often a third of patients with syncope remain undiagnosed despite assessments by multidisciplinary teams and the availability of various screening techniques such as electrocardiography, 24-h Holter monitoring, carotid sinus massage, echocardiography, exercise testing, head-up tilt test, and electrophysiological studies. Recently, ICM's have been developed to continuously monitor heart rhythm and thus aid in the diagnoses and management of clinical conditions such as ventricular arrhythmias, cryptogenic stroke, recurrent unexplained syncope and for monitoring atrial fibrillations (AF) post ablation. ICM's such as Confirm Rx from Abbott are leadless devices that detect arrhythmias largely depending on sensing of changes in R-R interval and R wave amplitude in the ECG signal. Whilst ICM's have been helpful in detecting arrhythmias in up to 40% of these patients with unexplained syncope, there is paucity of data regarding changes in signal quality with variations in body posture, physical activity and device movements that could potentially have effects on ECG signal and thus event detection. To this extent, this is an Abbott sponsored prospective, single arm, non-randomized, open-label, multi-center, clinical trial of 100 subjects designed to characterize the safety and performance of Confirm Rx™ in relation to physical activity and posture in these subjects with unexplained syncope.

ConfirmRx™ has come a long way since its inception with a significant reduction in size (78% reduction by volume) that has led to relatively simple insertion procedures through a small skin incision. The less complicated insertion process permits the insertion procedure to take place in settings besides operating rooms and furthermore, smaller devices are associated with significantly lower incidence of infections. We believe that this study will add to growing body of evidence of the efficacy of ConfirmRx.

The primary objective of this clinical investigation is to characterise the safety and performance of the Confirm Rx™ Insertable Cardiac Monitor (ICM) by assessing quality of signal attained from device post implant with changes in posture and physical activity at implant and 30days post procedure.

Primary Endpoints

* Changes in R-wave amplitudes at time of insertion and 30 days post-insertion.
* Changes in R-wave amplitude with below defined movements at time of insertion, and 30days post-insertion.

To identify any gross migration of Confirm Rx device 30 days following implant. Secondary Endpoints

* Change in measured distance/position of scar relative to distance from left lateral sternal border at baseline and 30 days
* Measurement of tip of device from left lateral sternal border
* Deviation of proximal tip of device from scar compared to baseline

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: