Brief Title: Application of 3D Printing Guide Plate in Endoscopic Spinal Surgery
Sponsor: Peking University Third Hospital
Organization:

Study Overview

Official Title: Application of 3D Printing Guide Plate in Endoscopic Spinal Surgery
Status: UNKNOWN
Status Verified Date: 2022-09
Last Known Status: NOT_YET_RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Application of 3D printing guide plate in endoscopic spinal surgery
Detailed Description: This study applies 3D-printed customized guide plate in assisting the accurate puncture in endoscopic spinal surgeries, in patients with low back pain, lumbosacral radicular pain, abnormal sensation or muscle strength or reflex of lower extremity, cauda equina syndrome, etc. This technique can shorten reduce the intra-operative radiation, and do not affect the surgical outcome.

This study involved diseases such as lumbar disc herniation, lumbar spinal stenosis, radiculopathy, disc degeneration, etc. Endoscopic spinal surgeries are effective treatments for these disease. Needle Puncture is the key technology in endoscopic spinal surgeries.

In the past when there were no customized guides, the surgeons would place the needle according to his/her previous experience under the guidance of C-arm fluoroscopy or CT. If the position of the needles is not satisfactory, repeated procedure will be performed. This would lead to an increase in the duration of surgery and intra-operative radiation, which is detrimental to both the surgeon and the patient. This problem could be well solved by applying the 3D printing guide plate.

The key processes for the 3D printing guide plate procedure: the model of the spine or bone is established according to the patient's CT scan data to prepare the customized guide plate, then sterilize them for future use. The final position of needle is confirmed by C-arm fluoroscopy or CT or evoked pain.