Viewing Study NCT03460535


Ignite Creation Date: 2025-12-24 @ 10:04 PM
Ignite Modification Date: 2025-12-25 @ 7:40 PM
Study NCT ID: NCT03460535
Status: UNKNOWN
Last Update Posted: 2018-03-09
First Post: 2018-02-26
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: The Rhytmia System to Determine the Precise Location and Potential Mechanism of Premature Contractions
Sponsor: University Hospital, Toulouse
Organization:

Study Overview

Official Title: Use of the Rhytmia System for Determining the Precise Location and Potential Mechanism of Premature Ventricular Contractions
Status: UNKNOWN
Status Verified Date: 2018-03
Last Known Status: RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: RhytmiaPVC
Brief Summary: This is a purely observational project and the objectives are to record and analyze the local potentials at the site of Premature Ventricular Contraction (VPC) focus through the Rhythmia system, ti determine the short and long-term success of the procedure and compare it to the existing literature about standard procedures, to highlight the advantages of the system compared to conventional mapping and to characterize optimal pace map or activation map as achieved by the Rhythmia system.
Detailed Description: This is a purely observational study. No special methodology choice, no comparison.

The study want to find the determination of precise location of the focus and mechanisms involved constitutes a challenge for conventional electrophysiology, even with tridimensional systems, because of the time needed for accurate delineation of the location (due to the sometimes unfrequent Ventricular Premature Beats (VPB)) and to the insufficient mapping density or inadequate signal characteristics. The Rhythmia system could allow better determination of the focus location in relation to the anatomical structures, especially with unfrequent VPB, because of the available high density mapping due to the number of closed high-resolution electrodes located on the Orion catheter. Better delineation of the true focus origin and of the mechanisms involved (automaticity vs re-entry) may be of useful help for better understanding and efficient therapy.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?:

Secondary ID Infos

Secondary ID Type Domain Link View
2017-A00777-46 OTHER ID-RCB View