Viewing Study NCT01429532


Ignite Creation Date: 2025-12-24 @ 10:00 PM
Ignite Modification Date: 2025-12-25 @ 7:37 PM
Study NCT ID: NCT01429532
Status: COMPLETED
Last Update Posted: 2014-07-11
First Post: 2011-09-04
Is NOT Gene Therapy: False
Has Adverse Events: True

Brief Title: Outcomes of 3 Incision-size-dependent Phacoemulsification Systems
Sponsor: Sun Yat-sen University
Organization:

Study Overview

Official Title: Clinical Evaluation of Three Incision-size-dependent Phacoemulsification Systems
Status: COMPLETED
Status Verified Date: 2014-06
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The purpose of this study is to compare the outcomes of cataract surgery performed with three incision-size-dependent phacoemulsification systems (1.8, 2.2 and 3.0 mm).
Detailed Description: It is generally the case that smaller corneal cataract surgical incisions are associated with more rapid wound healing, more stable corneal biomechanical properties and less surgically induced astigmatism (SIA). With the development of phacoemulsification and foldable intraocular lenses (IOL) during recent decades, the size of clear corneal incisions has been reduced from 3.2-mm (coaxial small incision) to 1.4-mm (bimanual micro incision). Micro incision cataract surgery (MICS), including bimanual and micro coaxial phacoemulsification, has attracted much interest recently, due to its safety and ease of learning. However, the superiority of coaxial micro incision cataract surgery as compared conventional coaxial cataract surgery is still not certain, because micro incision phacoemulsification may result in longer ultrasound time (UST), the use of more ultrasonic power and consequently higher endothelial cell loss (ECL).

In our previous studies of the OZil Torsional phacoemulsification system (Infinity, Alcon), we reported that the safety and effectiveness of cataract surgery are influenced by many factors, including the blade used to create the incision, the phacoemulsification apparatus, and the IOL and mode of IOL delivery, which together constitute a surgical system, whose outcomes are restricted by the best performance of each component. Today, micro coaxial phacoemulsification is in wide use for cataract surgery, but the lower limits of incision size should be understood in the context of the various components of the surgical system.

In this study, we compared the safety and efficacy of three different incision-size-dependent phacoemulsification systems, 1.8, 2.2 and 3.0 mm, and evaluated the relationship between incision size and SIA.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: