Brief Title: Optimum Length of Catheter in the Epidural Space for Labor Analgesia in Non-obese Women: a Randomised Controlled Trial of 4 Cm Versus 5 Cm
Sponsor: Samuel Lunenfeld Research Institute, Mount Sinai Hospital
Organization:

Study Overview

Official Title: Optimum Length of Catheter in the Epidural Space for Labor Analgesia in Non-obese Women: a Randomised Controlled Trial of 4 Cm Versus 5 Cm
Status: RECRUITING
Status Verified Date: 2025-03
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Epidural analgesia was introduced to the world of obstetrics in 1909 by Walter Stoeckel. Over the following 100 years it has developed to become the gold-standard for delivery of intra-partum analgesia, with between 60 and 75% of North American parturients receiving an epidural during their labor. Effective labor analgesia has been shown to improve maternal and fetal outcomes. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space. Dislodgement or displacement of epidural catheter remains a significant cause for failure with analgesia. Novel methods of fixation may further reduce the risk of catheter migration. Another factor is the direction of travel within the epidural space, only 13% of lumbar catheters remain uncoiled after insertion of more than 4 cm into the epidural space.

Hypothesis: The investigators hypothesize that catheters inserted to 4 cm will have a lower rate of failure when compared to those inserted to 5 cm.

Objective: This study aims to evaluate the difference in quality of labor analgesia delivered by epidural catheters inserted to either 4 or 5 cm into the epidural space.

This study will be conducted as an interventional double-blinded randomised control trial to establish best practice.
Detailed Description: Effective labor analgesia has been shown to improve maternal and fetal outcomes. It is of paramount importance to the obstetric anesthesiologist to optimize the quality of labor analgesia and identify any factors leading to ineffective epidural analgesia. One aspect of catheter insertion that has not been fully evaluated, and with very little recent work undertaken, is the optimal length of epidural catheter to be left in the epidural space.

Previous studies have advocated, for varying reasons, different lengths of catheter to be left in the space; these range from 2cm to 8cm. Longer epidural lengths in the space can be associated with foraminal escape, leading to unilateral block, and intravascular insertion, prompting additional manipulation. Shorter lengths have previously been associated with more frequent dislodgement. The directionality of the epidural catheter once in the space has been demonstrated to correlate with misdirection.

The aim of the study would be to standardize practice in how much epidural catheter is threaded into the epidural space.