Brief Title: Study of New Catheter Pressure Monitor System to Help Prevent Compartment Syndrome From Developing in the Injured Leg
Sponsor: Twin Star Medical Inc
Organization: Twin Star Medical Inc

Study Overview

Official Title: Randomized Clinical Trial of Tissue Ultrafiltration and Pressure Monitoring for the Diagnosis and Prevention of Compartment Syndrome
Status: UNKNOWN
Status Verified Date: 2009-02
Last Known Status: RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: TS2
Brief Summary: An investigation of a new catheter and pressure monitor system that may help to prevent a complication called compartment syndrome from developing in an injured leg Compartment syndrome occurs when too much fluid builds up in the muscles of the injured leg This causes a lot of swelling and increases pressures within the leg that can cause permanent damage muscles and nerves in the leg
Detailed Description: Compartment Syndrome CS may occur in patients with a fracture or crushing injury to an extremity The current standard-of-care for patients at risk of developing CS is clinical by watching for signs and symptoms of CS and if needed measuring the pressure within the muscle compartment intramuscular pressure IMP Currently IMP measurements are made by placing a percutaneous pressure sensor into the targeted muscle compartment which is then attached to a pressure monitor Whenever the clinical exam andor pressure measurements suggest that CS is developing fasciotomy is generally performed immediately

Twin Star Medical has developed a novel Compartment Monitoring System CMS that consists of a pressure monitoring module and two types of catheters Both Twin Star Catheters remove interstitial tissue fluid which may contribute to a reduction in compartment pressure and which may be used for clinical analysis to determine if certain analyte indicators of muscle injury biomarkers can be predictive of CS development One type of catheter Pressure MeasurementFluid Collection PMFC removes fluid and monitors pressure via a solid-state fiber optic transducer at the tip of the catheter The other type of catheter Fluid Collection FC only removes fluid and does not have a pressure transducer at the tip The monitoring module senses displays and records pressure as measured by the PMFC catheter as well as provides a vacuum source which is required for the operation of the fluid removal catheter The Twin Star CMS Monitoring Module has been successfully tested to 1 ensure the delivery of the specified functional performance requirements needed to reliably operate the Twin Star Catheter and 2 meet current electrical safety standards established for clinical use The first model of the Twin Star catheter and monitor was reviewed and approved by the Food and Drug Administration FDA for the indications of pressure measurement and the withdrawal of interstitial fluid The devices being used for this clinical study represent the newly designed catheter and monitor and are not FDA approved and are therefore considered investigational It is anticipated that the second-generation model of the catheter and monitor will be submitted to the FDA for approval while this study is being conducted

The purpose of this Study is to determine if the removal of interstitial fluid by the Twin Star Catheter can lower muscle compartment pressure and impact other measures of subject clinical status including possible reduction of the need for fasciotomy The Study population will be Subjects who have suffered an isolated tibial fracture open or closed requiring surgical stabilization within 72 hours of injury This Study will use an Adaptive study design in which a total of up to 90 subjects will be enrolled All Subjects will receive the Twin Star catheters which will be inserted at the end of the surgical procedure to stabilize the tibia fracture and will be connected to the pressure monitor before leaving the surgical room The catheters will be used for the first 24-hours after surgical fixation of the affected lower leg in order to 1 measure and record muscle compartment pressure and 2 remove accumulated interstitial fluid in the subset of subjects that are randomized to the Treatment Group The first 20 Subjects Phase 1 will not be randomized all will be actively treated but with different combinations of catheters and vacuum levels The purpose of Phase I of the study is to optimize treatment parameters that will be used in the remaining 70 subjects which will constitute Phase II All subjects will receive a total of 3 catheters placed in the anterior compartment Subjects in Phase 1 will be enrolled into two groups 1 receiving constant vacuum -150 mmHg and fluid removal or 2 receiving intermittent vacuum -50 mmHg and fluid removal Within the anterior compartment there will be one PMFC and 2 FC catheters inserted

The first 10 subjects in Phase 1 will all be treated with single-fiber catheters but with one of two different vacuum levels intermittent at -50 mmHg or constant at -150 mmHg After the first 10 subjects have completed the study fluid removal results will be analyzed If results demonstrate that fluid in the anterior compartment is being withdrawn at a rate of 05 mls24 hours the second group of 10 subjects will continue using the same single fiber catheters If the results of the first 10 subjects demonstrate fluid is being withdrawn in the anterior compartment at 05 mls24 hours the next 10 subjects will instead receive treatment with two multi-fiber FC catheters plus the same PMFC catheter

After the first 20 subjects have been enrolled in the study the remaining subjects to be enrolled in Phase 2 will be randomized to either a Treatment or Control group Both groups will receive treatment with whichever combination of catheter type single or multi-fiber and vacuum constant or intermittent was most efficacious in terms of fluid removal in Phase 1 The randomization will determine whether subjects will receive no vacuum at all Control Group Monitoring alone or the fluid removal mode that was shown to be best in the first phase of the study Treatment Group Monitoring plus Fluid Removal

The rationale for the adaptive study design is that we have developed second-generation catheters whose fluid removal function has not been optimized in vivo in humans Although our first generation catheter used multi-fibers animal study results have demonstrated that single-fiber catheters remove the same amount of fluid in vivo as multi-fiber catheters but can be made much smaller than multi-fiber catheters

The Subjects length of initial hospital stay will be determined by the attending physician based on the subjects medical conditions The standard-of-care for routine clinical compartment pressure monitoring will apply to both the vacuum and non-vacuum groups in this Study with the catheters being left in place for 24 hours Compartment syndrome is a dignosis that depends on clinical assessment supplemented by pressure measurement Throughout the study the treating physicians will monitor the subjects according to standard clinical practice and will apply standard clinical judgment regarding the diagnosis of compartment syndrome Treating physicians may end the study and perform fasciotomy if they feel it is necessary because of clinical suspicion that compartment syndrome is developing A two-week and a 3-month follow-up visit will be required post discharge coinciding with typical clinical follow-up visits The purpose of the two-week visit will be primarily to assess whether there have been any adverse consequences related to the catheter The purpose of the three-month assessment will be primarily to look for any evidence of the sequelae of missed or untreated compartment syndrome such as clawing of the toes or persistent neurologic dysfunction Functional outcomes will be measured during these follow-up visits as well as the occurrence of any adverse events since discharge Functional outcomes will include an assessment of whether any loss of motor function resulted as part of the primary injury

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None
Secondary IDs
Secondary ID Type Domain Link
Award W81XWH-07-1-0243 None None None
DoD Proposal06275001 None None None