Viewing Study NCT04707404


Ignite Creation Date: 2025-12-24 @ 9:12 PM
Ignite Modification Date: 2025-12-31 @ 8:36 PM
Study NCT ID: NCT04707404
Status: COMPLETED
Last Update Posted: 2021-01-13
First Post: 2021-01-12
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Comparison of Cranioplasty With PEEK and Titanium
Sponsor: RenJi Hospital
Organization:

Study Overview

Official Title: COMPREHENSIVE EVALUATION FOR CRANIOPLASTY WITH POLYETHERETHERKETONE AND TITANIUM IMPLANTS
Status: COMPLETED
Status Verified Date: 2021-01
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Decompressive craniectomy is suggested as an effective surgical intervention for patients with high intracranial pressure. Recently, various customized artificial materials are increasingly employed, e.g., titanium and polyetheretherketone (PEEK). The application of PEEK in cranioplasty is increasing, while its comprehensive evaluation in clinical practice is still insufficient, especially when comparing with the effects of titanium implant. We thus designed the study to evaluate the comprehensive effects of the cranioplasty with PEEK vs titanium.
Detailed Description: Decompressive craniectomy (DC) is suggested as an effective surgical intervention for patients with high intracranial pressure. For the skull defect after DC, cranioplasty could pro-vide protection, aesthetic and even functional improvements. The autologous bone flap (ABF) was once thought to be an optimal autograft for repairing \[8\]. While accumulated studies reported ABF related disadvantages. Recently, various customized artificial materials are increasingly employed, e.g., titanium and polyetheretherketone (PEEK).

Titanium is a widely applied metal material for cranioplasty, attribute to its high strength, bio-compatibility and comparatively low material cost. Currently, pre-operative three dimensional (3D) reconstruction of titanium brings a customized implant for optimal shaping effect. However, titanium implant is still confronted with complications of infection, implant exposure, etc.

PEEK is a novel polymer used to rebuild the personalized construction. Through the precise computational reconstruction of high-resolution computed tomography (CT) scanning, the customized PEEK could more accurately rebuild the complex cranial and maxillofacial structure. The application of this material in cranioplasty is increasing, while its comprehensive evaluation in clinical practice is still insufficient, especially when comparing with the effects of titanium implant.

We thus designed the study to evaluate the comprehensive effects of the cranioplasty with PEEK vs titanium. The data of the patients implanted PEEK or titanium in four years in our institute were retrospectively collected and evaluated, in respects of the general information of patients, postoperative complications, shaping effects, and psychosocial improvements, to display a comprehensive evaluation for these two implants.

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: