Viewing Study NCT01099761


Ignite Creation Date: 2025-12-24 @ 1:05 PM
Ignite Modification Date: 2025-12-31 @ 6:24 AM
Study NCT ID: NCT01099761
Status: TERMINATED
Last Update Posted: 2022-10-13
First Post: 2010-04-02
Is NOT Gene Therapy: True
Has Adverse Events: True

Brief Title: Study of ACE-031 in Subjects With Duchenne Muscular Dystrophy
Sponsor: Acceleron Pharma, Inc., a wholly-owned subsidiary of Merck & Co., Inc., Rahway, NJ USA
Organization:

Study Overview

Official Title: A Randomized, Double-Blind, Placebo-Controlled, Multiple Ascending-Dose Study to Evaluate the Safety, Tolerability, Pharmacokinetics, and Pharmacodynamics of ACE-031 (ActRIIB-IgG1) in Subjects With Duchenne Muscular Dystrophy
Status: TERMINATED
Status Verified Date: 2022-09
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Based on preliminary safety data.
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The purpose of this study is to determine if ACE-031 is safe and well-tolerated in boys with Duchenne Muscular Dystrophy (DMD) and to select the optimal doses of ACE-031 in terms of safety and pharmacodynamic (PD) activity for designing future studies. \[Note: This study was terminated based on safety data\]
Detailed Description: ACE-031, a soluble form of the human activin receptor type IIB, was administered once every 2 to 4 weeks by subcutaneous (SC) injection to boys with DMD. Dose levels and regimens for this multiple-dose study were based on data from the initial clinical studies in healthy subjects in which doses of 0.02 to 3 mg/kg SC were evaluated. A total of 24 subjects were enrolled into the study; 18 received ACE-031 and 6 placebo. All subjects were treated for a period of 12 weeks.The pharmacodynamic effects of ACE-031 treatment were assessed by a battery of motor function test that included the 6-Minute Walk Test, the 10-Minute Walk/Run Test, the 4-Stair Climb Test and the Gower Maneuver (GW). Muscle strength was assessed by hand-held myometry and fixed system testing. Body composition (i.e., spine BMD, lean mass, and fat mass) was assessed by whole body and lumbar spine DXA scans. Pulmonary function was assessed by forced vital capacity (FVC), maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP). ACE-031 safety was evaluated through observation of the incidence and severity of adverse events.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: