Viewing Study NCT01856504


Ignite Creation Date: 2025-12-24 @ 9:07 PM
Ignite Modification Date: 2025-12-25 @ 6:58 PM
Study NCT ID: NCT01856504
Status: COMPLETED
Last Update Posted: 2015-04-03
First Post: 2013-05-15
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Validation of an Intracycle CT Motion CORrection Algorithm for Diagnostic AccuracY
Sponsor: MDDX LLC
Organization:

Study Overview

Official Title: Validation of an Intracycle CT Motion CORrection Algorithm for Diagnostic AccuracY: A Prospective Multicenter Study
Status: COMPLETED
Status Verified Date: 2015-03
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: VICTORY
Brief Summary: To demonstrate the incremental utility of SSF for individuals undergoing CCTA, with expected improvements in image quality and diagnostic accuracy.
Detailed Description: Hypothesis: Coronary CT angiography (CCTA) employing a novel intracycle motion compensation algorithm (SnapShot Freeze \[SSF\]) will be superior to CCTA without an intracycle motion compensation algorithm ("conventional" CCTA) for diagnostic accuracy and image quality.

Scientific Basis: Preliminary study (Leipsic, Min, Journal of Cardiovascular Computed Tomography \[in press\]) of coronary CT angiograms in individuals undergoing pre-procedural assessment for transcatheter aortic valve replacement (n=36) demonstrate improved image quality of CCTA using SSF compared to CCTA not using SSF. Importantly, individuals in this study did not receive heart rate slowing agents (e.g., beta blockers), and diagnostic image quality was substantially improved. While not statistically powered on a per-patient basis, per-segment diagnostic accuracy of CCTA using SSF was superior to conventional CCTA. These results are complementary to those derived from internal testing at GE Healthcare wherein phantom work has demonstrated improved diagnostic performance using SSF compared to conventional image acquisitions.

Long-term Goal/Purpose: To demonstrate the incremental utility of SSF for individuals undergoing CCTA, with expected improvements in image quality and diagnostic accuracy. If the aims of this study are achieved, the use of SSF for effective temporal resolution improvement may obviate (or reduce) the need for CT hardware for improved temporal resolution.