Viewing Study NCT04682704


Ignite Creation Date: 2025-12-24 @ 7:52 PM
Ignite Modification Date: 2025-12-30 @ 2:57 PM
Study NCT ID: NCT04682704
Status: RECRUITING
Last Update Posted: 2024-02-21
First Post: 2020-12-08
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: The Effect of Different Low-Level Tragus Stimulation Parameters On Autonomic Nervous System Function
Sponsor: University of Oklahoma
Organization:

Study Overview

Official Title: The Effect of Different Low-Level Tragus Stimulation Parameters On Autonomic Nervous System Function
Status: RECRUITING
Status Verified Date: 2024-02
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: LLT-SPANS
Brief Summary: Low level transcutaneous vagus nerve stimulation (LLTS) involves delivery of electrical impulses transcutaneously at the auricular branch of vagus nerve and it has been shown to have anti-inflammatory and anti-arrhythmic effects. In previous studies from our laboratory, we found that LLTS significantly suppressed atrial fibrillation (AF) inducibility and decreased AF duration. The anti-arrhythmic effects of LLTS were similar to those delivered to the cervical VN trunk. LLTS for just one hour significantly shortened the AF duration and decreased inflammatory cytokines. We have also shown that LLTS leads to favorable heart rate variability (HRV) changes and cardiac mechanics in patients with diastolic dysfunction. These results support the use of LLTS as a novel non-pharmacological, non-ablative treatment modality for AF and possibly other inflammatory conditions. However, the optimal stimulation parameters of LLTS remain to be determined.

In this study, we aim to examine the effect of 2 different frequencies (5Hz and 20Hz) and 2 different amplitudes (50% below the pain threshold and 1mA below the pain threshold) of LLTS on heart rate variability with deep breathing (HRVdb), mental arithmetic stress test (MAST), frequency domain measures of heart rate variability (HRV) and brain stem evoked potentials (BSEVP) in healthy volunteers and patients with AF or heart failure with preserved ejection fraction (HFpEF). HRV is a marker of vagus nerve activity and can be easily measured by software calculating the distance between consecutive R waves on the ECG. BSEVP are a surrogate for the central projections of the vagus nerve. Patients will be randomized into 4 groups in a 2x2 factorial design. LLTS will be delivered through a transcutaneous electrical nerve stimulation (TENS) device for 15 minutes. HRVdb, HRV and BSEVP will be measured before and after LLTS and compared.
Detailed Description: None

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: True
Is an Unapproved Device?: True
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: