Viewing Study NCT06625424



Ignite Creation Date: 2024-10-26 @ 3:41 PM
Last Modification Date: 2024-10-26 @ 3:41 PM
Study NCT ID: NCT06625424
Status: RECRUITING
Last Update Posted: None
First Post: 2024-10-01

Brief Title: Effect of Short Sprint Interval Training With Active Recovery as Compared to Passive Recovery on Anaerobic Capacity in Non-athletic Population
Sponsor: None
Organization: None

Study Overview

Official Title: Effect of Short Sprint Interval Training With Active Recovery as Compared to Passive Recovery on Anaerobic Capacity in Non-athletic Population
Status: RECRUITING
Status Verified Date: 2024-10
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: No
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Short Sprint Interval Training SSIT is a modified form of Sprint Interval Training SIT defined as small bouts of supramaximal exercise with recovery periods between them to increase peak oxygen uptake in spite of having a less amount of exercise volume SSIT was developed so that non- athletic population could also perform a training which was originally designed for athletes to increase anaerobic capacity The benefit of this type of exercise is that it is time efficient and yields the result in short amount of time as compared to other type of exercises due to its vigorous nature Moreover this sort of training is mostly performed in lab setting rather than on field therefore the aim of this study is to determine the effect of short sprint interval training in a field with active recovery as compared to passive recovery on anaerobic capacity in non-athletic population
Detailed Description: Based on a global health initiative to promote Exercise is Medicine strategy by American College of Sports Medicine designing an exercise prescription which is time efficient cost-effective easily performable and has great adherence or compliance is necessary SIT is a type of Anaerobic training which not only enhances the anaerobic capacity but also the aerobic capacity of an individual as well Thus SIT plays a crucial role in prevention of the NCDs by maintain and improving CRF Classic SIT is limited to athletic population therefore this study aims to promote the use of modified SIT training protocol called as SSIT by shortening the sprinting time from 30s to 10s so that non-athletic individuals are able to perform it Apparently there are lack of field based studies on SIT Most studies use lab based training performed on treadmill and cycle ergometer which can be expensive and time-consuming especially when several subjects have to train at the same time Furthermore no comparison has been made between active and passive recovery in short term sprint interval training in field a bout of 10 second of less This study aims to test the novel effects of Short Sprint Interval Training with two different types of recovery method performed on field rather than lab to enhance anaerobic capacity in a short amount of time

This study would be a single blinded randomized control trial conducted over a period of 12 months at football ground at F-111 Islamabad Subjects will be selected via non-probability convenience sampling technique followed by block randomization into two groups the intervention group A and intervention group B using sealed envelope method The sample size as calculated by GPower software will be 38 non -athletic individuals Informed consent will be taken from individuals selected as per inclusion criteria Participants then being allocated to one of the 2 groups will be required to complete a self-reporting demographic form For training participants will perform SSIT 3 times a week for a total duration of 02 weeks Anaerobic capacity of the participants will be measured using running based anaerobic sprint test RAST before intervention and after intervention of two weeks Collected data will then be entered and analyzed on the SPSS software version 23

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None