Viewing Study NCT06527664



Ignite Creation Date: 2024-10-26 @ 3:36 PM
Last Modification Date: 2024-10-26 @ 3:36 PM
Study NCT ID: NCT06527664
Status: NOT_YET_RECRUITING
Last Update Posted: None
First Post: 2024-07-23

Brief Title: Innovative Technologies for Salvage Procedures of Failed Treatments of Osteoarthritis Biomimetics Solutions CustomPN
Sponsor: None
Organization: None

Study Overview

Official Title: Innovative Technologies for Cost-Effective Healthcare Delivery for Salvage Procedures of Failed Treatments of Osteoarthritis Specific Biomimetics Solutions to Reduce a Growing Problem With a High Social and Economic ImpactCustomPN
Status: NOT_YET_RECRUITING
Status Verified Date: 2024-07
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: No
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: CustomPN
Brief Summary: In this prospective multicenter study a population of adult individuals consecutively treated for revision hips requiring a custom-made acetabular implant for non-oncological reasons will be included The custom-made implant is a personalized implant produced using additive manufacturing based on the pre-operative CT scan that details the bone damage Patients eligible for this implant are those with severe acetabular bone damage Paprosky 3 loss of the superolateral part and one of the two ventro-caudal walls

Preoperatively the patient will undergo a clinical evaluation Data will be collected on the patients general health status with the Charlson score the reason for revision number of revisions type of implant in place and the time elapsed between the failed implant and the revision in question The bone deficit will be studied through CT measurements according to qualitative and quantitative scales During the surgery information on intraoperative complications will be collected In the postoperative period perioperative complications will be collected according to the Clavien Dindo classification The clinical radiographic evaluations will be carried out during outpatient follow-up visits at 1 3 12 24 and 36 months after revision They include the Harris Hip Score clinical score the EQ-5D PROM and the patients satisfaction level qualitative assessment in 4 grades unsatisfied slightly satisfied moderately satisfied fully satisfied The positional parameters of the implant will be evaluated as compared to the immediate post-operative X-ray acetabular abduction acetabular anteversion center of rotation height center of rotation medialization and inclination of the custom-made component From 12 months onwards the osteointegration characteristics of the component will be assessed presence of radial trabeculae at the interface superolateral and inferior reinforcements stress shielding absence of radiolucent lines Re-revision rates will be determined using the Kaplan-Meier method The reasons for re-revision will be noted
Detailed Description: Osteoarthritis OA increased from 24751 million people in 1990 to 52781 million in 2019 OA places a huge burden on healthcare services accounting for 1-25 of the gross national products and the cost is expected to quadruple by 2030 Total joint replacement TJR represents the standard of care of end-stage OA TJR is projected to nearly double by 2026 Unfortunately TJR are subject to failure thus the number of revision procedures is also growing accounting for 5-6 of all TJR Failure of TJR represents a dramatic event for patients and National Health Systems Patients suffer enormous disability with impact on function emotional sphere and loss of autonomy The average cost of treatment is almost doubled compared to TJR and in case of periprosthetic joint infections almost tripled In patients under 65 years with a failure rate of 9-12 the full return to work is reported only in 7-33 of the cases and not earlier then 1 year after the surgery while around 50 retired or remained on welfare benefits Current technology is not enough to overcome this set of problems while actual projections predict a 43-70 increase in revisions by 2030 In particular revision hips involve various diagnoses and settings in some cases the severe bone loss makes the reconstruction very complex In these cases acetabular reconstruction can be performed with off-the-shelf implants but outcomes are not always consistent and reproducible Thus in cases of severe acetabular bone loss it may be very useful to proceed with a customized implant designed according to the patients needs Implants produced in this way are designed based on the patients pre-operative CT scan using additive manufacturing technology The purpose is to offer a personalized bone filling of the defect with a highly porous interface that promotes osteointegration Currently most of the custom-made implants are performed for oncological cases On the contrary there are few indications on the clinical and radiological outcomes of custom-made acetabular reconstructions in revision hips with severe bone loss in non-oncological cases The purpose of this project is to validate an innovative and reliable technology custom-made acetabular component produced using additive manufacturing for managing non-oncological revisions assessing short term outcomes

The aims are

Description of demographic characteristics and bone defect in candidates for acetabular reconstruction with custom-made implants Perioperative complications and implant survival Clinical evaluation of custom-made implants in custom-made acetabular reconstructions in hip prosthesis revisions with severe bone loss clinical score Harris Hip Score subjective score PROM EQ-5D post-operative patient satisfaction level Radiographic evaluation positioning and osteointegration of custom-made implants in custom-made acetabular reconstructions in hip prosthesis revisions with severe bone loss This is a prospective multicenter study The study population will consist of adult individuals consecutively treated for revision hips requiring a custom-made acetabular implant Patients with a diagnosis leading to an oncological revision will not be included The custom-made implant is a personalized implant created by an external company based on the pre-operative CT scan that details the bone damage Patients eligible for this implant are those with severe acetabular bone damage Paprosky 3 loss of the superolateral part and one of the two ventro-caudal walls In these cases off-the-shelf therapeutic options are limited and achieve uncertain outcomes therefore a custom-made component with ultra-porous anchoring surfaces can represent a highly advantageous therapeutic choice After identifying the suitable patient and obtaining their consent for the study a pre-operative CT scan will be performed as per normal clinical practice for every revision After uploading it to the dedicated website or app of the company this CT scan will be used for the manufacturing of the custom-made implant by a third-party company The company will also provide plastic phantoms for preliminary study of the implant Upon approval of the implant production the company will manufacture the implant according to current regulations and production techniques following previous and established clinical practice The device will be accompanied by personalized instrumentation such as cutting guides positioners calipers and plastic simulation phantoms to facilitate the surgical procedure The implant and the produced instrumentation will be delivered to the reference center after performing the patients surgical planning

Preoperatively the patient will undergo an evaluation with the Harris Hip score clinical score Additionally data will be collected on the patients general health status with the Charlson score the reason for revision number of revisions type of implant in place and the time elapsed between the failed implant and the revision in question The bone deficit will be studied through CT measurements according to qualitative and quantitative scales

During the surgery information on intraoperative complications will be collected In the postoperative period perioperative complications will be collected according to the Clavien Dindo classification The clinical radiographic evaluations will be carried out during outpatient follow-up visits at 1 3 12 24 and 36 months after revision They include the Harris Hip Score clinical score the EQ-5D PROM and the patients satisfaction level qualitative assessment in 4 grades unsatisfied slightly satisfied moderately satisfied fully satisfied The positional parameters of the implant will be evaluated as compared to the immediate post-operative X-ray acetabular abduction acetabular anteversion center of rotation height center of rotation medialization and inclination of the custom-made component From 12 months onwards the osteointegration characteristics of the component will be assessed presence of radial trabeculae at the interface superolateral and inferior reinforcements stress shielding absence of radiolucent lines Re-revision rates will be determined using the Kaplan-Meier method The reasons for re-revision will be noted

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None