Viewing Study NCT06635356



Ignite Creation Date: 2024-10-25 @ 7:57 PM
Last Modification Date: 2024-10-26 @ 3:42 PM
Study NCT ID: NCT06635356
Status: NOT_YET_RECRUITING
Last Update Posted: None
First Post: 2024-10-08

Brief Title: Knee Replacement and Sarcopenia
Sponsor: None
Organization: None

Study Overview

Official Title: Evaluation of Sarcopenia in Patients Undergoing Knee Prosthesis
Status: NOT_YET_RECRUITING
Status Verified Date: 2024-10
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: No
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The presence of sarcopenia in patients planned to undergo knee prosthesis and the effect of knee prosthesis on sarcopenia will be investigated
Detailed Description: Volunteer patients who will undergo knee replacement surgery in orthopedic clinics located in the Istanbul region and who meet the inclusion criteria will be recruited A total of 31 volunteers will be included in the study

First all patients will be asked about their gender age height weight education smoking lifestyle additional diseases and treatments they have received Then a brief orthopedic evaluation will be performed on the patient TANITA BIA analysis and grip strength measurement from the dominant hand will be performed on all patients before the operation at 1 month and 3 months after the operation Maximal voluntary grip strength will be measured with a hand dynamometer Measurements will be made three times For this measurement the subject will be asked to hold a maximal voluntary grip for five seconds There will be a ten-second rest period between the three tests Measurements will be made with the JAMAR Plus by Sammons Preston hand dynamometry device Before the test measurements the patient will be shown how to use the device as an application The highest of the three measured values will be taken In addition the calf circumference will be measured While the patient is standing the measurement will be made with a tape measure from the thickest point of the right and left calves without squeezing the skin The same measurement will be repeated with the patient seated At the same time patients will be evaluated with walking speed test sit-to-stand test SARC-F FRAIL Frailty Questionnaire Mini Nutritional Assessment EQ-5D General Quality of Life Scale GLIM Test Barthel Activities of Daily Living Index CIRS Scale before the operation 1st month and 3rd month after the operation

When performing the walking speed test the patient will be asked to walk as they normally do A 4-meter or 3-meter walking speed test will be performed and a single test will be scored Measurements will be made twice and the fastest will be evaluated

In the sit-to-stand test the person will be asked to try to get up without using their arms If they cannot complete the test or can get up using their arms the patient will receive 0 zero points If they can get up using their arms the repeated sit-to-stand test will be performed In the repeated sit-to-stand test the person will be asked to sit down and get up from a chair 5 times in a row without using their arms Scoring will be between 0-4 depending on the time spent

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None