Viewing Study NCT06449391



Ignite Creation Date: 2024-06-16 @ 11:50 AM
Last Modification Date: 2024-10-26 @ 3:31 PM
Study NCT ID: NCT06449391
Status: RECRUITING
Last Update Posted: 2024-06-10
First Post: 2024-05-27

Brief Title: The Application of Root Analogy Implant in Immediate Implantation
Sponsor: The Dental Hospital of Zhejiang University School of Medicine
Organization: The Dental Hospital of Zhejiang University School of Medicine

Study Overview

Official Title: A Clinical Exploratory Study of Root Analogy Implant
Status: RECRUITING
Status Verified Date: 2024-06
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: RAI
Brief Summary: The current clinical implant techniques used include immediate implantation early implantation and delayed implantation With the acceleration of the current pace of life immediate implantation is increasingly favored by patients due to its advantages such as fewer surgeries shorter waiting times and less impact on aesthetics The research group has shown that the mismatch between traditional implants and extraction sockets in immediate implantation surgery has caused some complications Therefore it is believed that 3D printed personalized root shaped implants with certain roughness are more suitable for use in immediate implantation surgery
Detailed Description: The current clinical implant techniques used include immediate implantation early implantation and delayed implantation With the acceleration of the current pace of life immediate implantation is increasingly favored by patients due to its advantages such as fewer surgeries shorter waiting times and less impact on aesthetics The research group has shown that the mismatch between traditional implants and extraction sockets in immediate implantation surgery has caused some complications Therefore it is believed that 3D printed personalized root shaped implants with certain roughness are more suitable for use in immediate implantation surgery A 3D printed personalized root implant system jointly developed by Zhejiang University School of Medicine Affiliated Stomatology Hospital Zhejiang University School of Mechanical Engineering and Hangzhou Ya Natural Technology Co Ltd The implant part of this implant system is implanted into the bone using laser melting printing technology in additive manufacturing methods The raw material is pure titanium powder and research results in New Zealand white rabbits and beagles have confirmed that the implant has good bone bonding ability which can shorten surgical time reduce surgical frequency compress implant cycle restore chewing function and other advantages The relevant research results have been published in the top oral journal Journal of Dental Research and the chemical composition and biological safety of the material have been tested by the Zhejiang Medical Device Inspection and Research Institute test report number Z20221903 Z20222527G20233158 The base and other accessories are cut from titanium rods using conventional reduction manufacturing techniques

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None