Brief Title: Cervical Length and Uterocervical Angle as Predictors of Spontaneous Preterm Birth
Sponsor: Beni-Suef University
Organization: Beni-Suef University

Study Overview

Official Title: Cervical Length and Uterocervical Angle as Predictors of Spontaneous Preterm Birth
Status: COMPLETED
Status Verified Date: 2024-05
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: This prospective study was carried out on 263 pregnant females aged from 19 to 35 years old carrying singleton and uncomplicated pregnancy TVS examination was performed in all cases at 28 and 32 weeks of gestation The pregnant women recruited in the study closely followed up to delivery Maternal progesterone was given to all women with short CL 20mm and more than 10mm to support pregnancy
Detailed Description: Patients and Methods This prospective cohort study was performed on 263 pregnant females aged from 19 to 35 years old carrying singleton and uncomplicated pregnancy

The study was done after approval from ethical committee An informed written consent was obtained from the patient

With aseptic measures and a high-frequency endo-vaginal 75 Hz probe GE Logiq P6 TVS examinations were done to all pregnant women Dorsal lithotomy posture was applied to pregnant women who were instructed to evacuate their bladders Without applying excessive pressure the vaginal probe was inserted into the anterior fornix At maximum magnification a sagittal image of the cervix and anterior uterine wall was obtained We identified the echogenic endocervical canal with the surrounded less echogenic cervical mucosa zone The external os was noted at the junction of the cervix both anterior and posterior lips within the vaginal canal but the internal os was situated at the end of the cervical mucosa in the lower uterine segment CL and UCA were measured using the ultrasounds built-in angle caliper The anterior UCA measurement involved calculating the angle formed by a line running through the cervix and another line along the lower front segment of the uterus starting from the internal os This was achieved by manually drawing two lines with the angle caliper one connecting the internal and external os and another extending from the internal os along the lower anterior uterine wall up to a point 3 cm from the internal os

The research involved close monitoring of pregnant participants up to the time of delivery Demographics and pregnancy outcomes were collected and recorded PTB was defined as delivery occurring before 37 complete weeks of gestation 9 To support pregnancy maternal progesterone was administered to all women with a short CL less than 20mm but more than 10mm In this study cervical cerclage was not used in any case

Sample Size Calculation

The sample size for the study was determined using the Open-Epi Version 3 an open-source software tool This calculation was based on the premise that 781 of patients with a cervical angle greater than 95 degrees experience preterm labor To ensure a confidence level of 95 and a margin of error of 5 it was necessary to include at least 263 patients in the study The confidence limits were set at 5 and the design effect was established at 1 The formula used for this calculation was n DEFFNp1-p d²Z²1-α2N-1 p1-p

Statistical analysis Statistical analysis was done by SPSS v26 IBM Inc Chicago IL USA Quantitative variables were presented as mean and standard deviation SD Qualitative variables were presented as frequency and percentage Correlation between various variables was done using Pearson coefficient The diagnostic performance was assessed using ROC curve analysis with the AUC serving as a predictor of sPTB