Viewing Study NCT00673803


Ignite Creation Date: 2025-12-24 @ 7:41 PM
Ignite Modification Date: 2026-01-04 @ 9:32 PM
Study NCT ID: NCT00673803
Status: COMPLETED
Last Update Posted: 2010-08-17
First Post: 2008-05-06
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Influence of Two Different Preloaded Intraocular Lens (IOLs) on Posterior Capsule Opacification
Sponsor: Hospital Hietzing
Organization:

Study Overview

Official Title: Influence of Two Sharp-edged Hydrophobic Acrylic Micro-incision-IOLs on Posterior Capsule Opacification. A Randomized, Double-masked Study With Intraindividual Comparison.
Status: COMPLETED
Status Verified Date: 2008-12
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Studies showed that a sharp posterior optic edge of an intraocular lens (IOL) inhibits migration of lens epithelial cells in between posterior capsule and optic of the IOL and therefore reduces the rate of posterior capsule opacification (PCO). In present time most IOLs implanted have a sharp posterior optic edge. Due to differences in IOL production different IOLs have different rates of PCO.

Progression in cataract surgery technique allow phacoemulsification through micro-incisions. Therefore there is need for IOLs that can be implanted through incisions of about 2.5 mm.

This study investigates the effect of two different hydrophobic acrylic IOLs with a sharp posterior optic edge on the rate of PCO after implantation through a micro-incision. The results will be compared intraindividually.
Detailed Description: prospective, randomized, bilateral study with intraindividual comparison, implantation of a Polylens Y10 IOL in one eye and implantation of a Polylens Y30 in the contralateral eye.

PCO rate will be detected at 1 year and 2 years.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: