Viewing Study NCT03584503


Ignite Creation Date: 2025-12-24 @ 7:22 PM
Ignite Modification Date: 2025-12-25 @ 5:01 PM
Study NCT ID: NCT03584503
Status: COMPLETED
Last Update Posted: 2018-12-04
First Post: 2018-06-19
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Effect of Use of Endotracheal Tube With Subglottic Suction in Rhinoplasty
Sponsor: Yuzuncu Yil University
Organization:

Study Overview

Official Title: Effect of the Use of Endotracheal Tube With Subglottic Suction on Laryngospasm and Postoperative Complications in Rhinoplasty Operations
Status: COMPLETED
Status Verified Date: 2018-12
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Suction Above Cuff Endotracheal Tube (SACETT) has a dorsal port above the cuff designed to allow continuous or intermittent suctioning of secretions from the subglottic space. Thus, it facilitates suctioning of excessive secretions around the mouth and the cuff. In this study, we aimed to investigate the effect of the use of SACETT on laryngospasm and postoperative complications in rhinoplasty operations. This randomized controlled clinical trial was conducted in 132 patients undergoing rhinoplasty.

The investigators believe that the use of SACETT in rhinoplasty operations reduces the incidences of laryngospasm, emergence agitation, sore throat, swallowing difficulty, and PONV when compared with classic endotracheal tube.
Detailed Description: Suction Above Cuff Endotracheal Tube (SACETT) has a dorsal port above the cuff designed to allow continuous or intermittent suctioning of secretions from the subglottic space. Thus, it facilitates suctioning of excessive secretions around the mouth and the cuff. In this study, the investigators aimed to investigate the effect of the use of SACETT on laryngospasm and postoperative complications in rhinoplasty operations.

This randomized controlled clinical trial was conducted in 132 patients undergoing rhinoplasty. The patients were randomly divided into 2 groups: Suction Above Cuff Endotracheal Tube (n:66) (Group SA) and classic endotracheal tube (n:66) (Group C). Complications following general anesthesia were statistically analyzed among the two groups.

55 male patients and 77 female patients were included in the study. The incidences of postoperative laryngospasm and respiratory complications were found to be lower in Group SA compared to Group C. In addition, the incidences of agitation, postoperative nausea and vomiting (PONV), swallowing difficulty, and sore throat were found to be lower in Group SA compared to Group C. However, the incidences of cough, hypotension, and tachycardia were similar in both groups. No PONV, swallowing difficulty, and hypotension were observed in Group SA. The blood volume accumulated in the suction chamber was found to be greater in Group SA compared to Group C.

The investigators believe that the use of SACETT in rhinoplasty operations reduces the incidences of laryngospasm, emergence agitation, sore throat, swallowing difficulty, and PONV when compared with classic endotracheal tube.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: