Viewing Study NCT06032169



Ignite Creation Date: 2024-05-06 @ 7:30 PM
Last Modification Date: 2024-10-26 @ 3:08 PM
Study NCT ID: NCT06032169
Status: COMPLETED
Last Update Posted: 2024-01-09
First Post: 2023-06-06

Brief Title: Ankle Measurements of Arterial Pressure Semi-recumbent or Horizontal Position
Sponsor: Nantes University Hospital
Organization: Nantes University Hospital

Study Overview

Official Title: NON-INVASIVE MEASUREMENT OF ARTERIAL PRESSURE AT THE ANKLE IMPACT OF POSITION SEMI-RECUMBENT OR HORIZONTAL A SINGLE-CENTER PROSPECTIVE STUDY
Status: COMPLETED
Status Verified Date: 2024-01
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: 2PAC
Brief Summary: The upper arm is sometimes inaccessible for arterial pressure AP measurement Placing the automatic cuff at the ankle is a common alternative However whether AP measurement at the ankle is reliable is uncertain Furthermore it is unknown whether it is necessary to place the patient in a horizontal position to improve the reliability of the measurement or if leaving the patient in default position often semi-recumbent is acceptable The aim of this study is to answer these questions Additionally investigators will evaluate whether a smartphone application that allows for the simple measurement of AP by gently placing a finger on the camera lens is a valuable alternative to upper arm measurements
Detailed Description: A question that arises relatively frequently is when the upper arm is inaccessible where should the investigators place the automatic cuff to measure AP Indeed surgical intervention involving the upper limb a wound a fracture or vascular access temporary catheter or arteriovenous fistula often makes the arm unsuitable for monitoring AP with an automatic cuff The arterial catheter is not devoid of risks including the loss of precious time for its insertion and is rarely an appropriate alternative at least in the first instance Thus the inaccessibility of the upper arm legitimates the frequent placement of the automatic cuff at the ankle However the automatic cuff has only been validated for placement at the upper arm not at the ankle Surprisingly the reliability of ankle AP measurements obtained by this positioning of the cuff at the ankle has been little studied only two studies using arterial catheter as the reference method are available one of which was in the specific population of patients with obesity These studies reported that the measurement error at the ankle was excessive but confirmation is necessary

Patients especially in acute care settings are rarely in a strictly horizontal supine position For various reasons the critically ill patient is rather in a semi-recumbent position meaning that the angle between the trunk and the horizontal axis is between 30 and 60 Thus the cuff placed at the ankle is no longer at the level of the heart and more precisely of the phlebostatic axis This could modify the hydrostatic pressure and lead to overestimation of AP compared to a measurement of AP at heart level on the arm or invasively for example Indeed the impact on AP measurement of the height of the upper arm relative to the heart has already been demonstrated the vertical displacement of the upper arm changes the measured AP value Does the angle of elevation of the trunk significantly modify the AP measured at the ankle If so and since the measurement at the ankle in the horizontal supine position 0 tends to underestimate AP do the different sources of measurement error cancel out in the semi-recumbent position In what position of the trunk is it preferable to measure AP at the ankle The answers to these questions are uncertain Indeed the only study that investigators are aware of a pilot study and that specifically addressed this issue did not provide clear answers This is important since AP is a crucial parameter of monitoring and therefore of therapeutic decision-making It is remarkable that in acute care settings little to no attention is paid to trunk elevation when measuring BP at the ankle and of course there is no automation of patient positioning eg in a horizontal position prior to each automatic measurement at the ankle

Therefore it appears important to evaluate the accuracy and precision of non-invasive ankle measurements of AP and the impact of patient position on it This will be the main objective of the study If these ankle measurements prove to be neither accurate nor precise having an alternative would be desirable It is noteworthy that when the arm is inaccessible the finger often is AP measurement at the finger is now possible with a simple smartphone This finger measurement requires calibration with one or two automatic cuff measurements which should be possible in most cases the arm is frequently inaccessible for prolonged AP monitoring but still allows for one or two isolated measurements So which is the better alternative site for AP measurement the finger or ankle AP measurement using a smartphone has never been evaluated from this perspective This will be a secondary objective of the study

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None