Viewing Study NCT07250503


Ignite Creation Date: 2025-12-24 @ 7:12 PM
Ignite Modification Date: 2025-12-25 @ 4:48 PM
Study NCT ID: NCT07250503
Status: ACTIVE_NOT_RECRUITING
Last Update Posted: 2025-11-26
First Post: 2025-11-18
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Compare the Difference in Occlusal Force Distribution and Denture Retention Using 2 Different Denture Base Materials in Implant Retained Overdenture
Sponsor: Al-Azhar University
Organization:

Study Overview

Official Title: Impact of Wearing Two Different Implant Retained Mandibular Overdentures on Occlusal Force Distribution and Denture Retention (Randomized Clinical Trial)
Status: ACTIVE_NOT_RECRUITING
Status Verified Date: 2025-11
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The global increase in the aging population has led to a rise in total edentulism, which remains a major public health concern. two-implant-retained mandibular overdentures have been regarded as the standard of care, offering superior retention, stability, comfort, and masticatory efficiency compared to conventional dentures. Among available attachment systems-bar, ball, stud, and magnet-the Equator attachment has gained popularity due to its low vertical profile, suitability for limited inter-occlusal space, and ease of handling.

Assessment of masticatory performance and occlusal balance can be objectively measured using devices such as bite force analyzers and the computerized T-Scan system, which quantifies occlusion and disocclusion times.

Conventional heat-cured polymethyl methacrylate (PMMA) remains the most widely used denture base material; however, it has mechanical and biological limitations. Flexible denture base materials have been introduced to overcome these drawbacks by enhancing adaptation, distributing occlusal loads more evenly, and improving comfort and retention.
Detailed Description: 24 Patients will be randomly and equally divided into two treatment groups:

1. Group 1: Each patient in this group will receive conventional maxillary and mandibular complete dentures made of heat-cured acrylic resin PMMA. In the mandible, two implants were inserted in the symphyseal area and retained by equator attachments.
2. Group 2: Patients in this group received the same type of treatment as the patients in group 1, but the mandibular overdentures were made of the flexible acrylic resin "breflex" The present study will be performed to compare the difference in retention, occlusal force distribution, occlusion and disocclusion time, and bite force for implant retained mandibular over denture using PMMA and flexible dentures base materials

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: