Viewing Study NCT05690763



Ignite Creation Date: 2024-05-06 @ 6:32 PM
Last Modification Date: 2024-10-26 @ 2:49 PM
Study NCT ID: NCT05690763
Status: COMPLETED
Last Update Posted: 2023-05-06
First Post: 2022-12-16

Brief Title: Quantitative Assessment of the Efficacy of Two Irrigation Activation Systems
Sponsor: Seyda Ersahan DDS PhD
Organization: Istanbul Medipol University Hospital

Study Overview

Official Title: Quantitative Assessment of the Efficacy of Two Irrigation Activation Systems in Reducing the Bacterial Load in Teeth With Post-treatment Apical Periodontitis A Clinical Study
Status: COMPLETED
Status Verified Date: 2023-05
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Aim of the present study was to determine the intraradicular microbiota of previously root canal-treated teeth with apical periodontitis using droplet digital polymerase chain reaction ddPCR and to investigate the antibacterial effectiveness of different irrigation activation methods XP-endo Finisher and EndoActivator that will make classical chemomechanical preparation more effective This superiority parallel randomized clinical trial was conducted in the clinic of the Endodontic Department Faculty of Dentistry Istanbul Medipol University Istanbul 20 patients with posttreatment apical periodontitis one tooth each were randomly allocated into two groups according to the used n10 for each the EA group A or the XPF group B Total bacterial loads as well as the amount of Enterococcus faecalis Efaecalis were determined before S1 and after S2 chemomechanical preparation and finally after intracanal medication S3 by means of ddPCR
Detailed Description: Eligibility criteria The study population consisted of 20 patients 9 women and 11 men aged 19-66 years presenting to the endodontic clinic at Istanbul Medipol University Dental School for nonsurgical endodontic retreatment of teeth with apical periodontitis lesions 20 previously root canal-treated teeth exhibiting clinical and radiographic evidence of chronic apical periodontitis lesions were included in this study Radiographically the diameter of the periapical radiolucency ranged from 2 to 7 mm Teeth with post-treatment apical periodontitis had endodontic therapy completed more than 2 years earlier and required retreatment Termini of the root canal fillings ranged from 0-4 mm short of the radiographic apex with no overfilling The teeth had intact coronal restorations with no obvious exposure of the root-filling material to the oral cavity Selected teeth had enough crown structure for adequate isolation with a rubber dam and showed an absence of periodontal pockets or attachment level deeper than 4 mm Exclusion criteria were also applied as follows teeth from patients who had received antibiotics within the previous 3 months or who had any general disease teeth that could not be properly isolated with rubber dam teeth with absence of coronary sealing teeth with periodontal pocket depth 4 mm and teeth with crownroot fracture Only one tooth was included from each patient

Root canal treatment procedures and sampling Rubber dam and an aseptic technique were used throughout the endodontic retreatment After plaque removal and rubber dam isolation the operative field was cleaned with 3 hydrogen peroxide and disinfected with 25 NaOCl solution Then all coronal restorations posts and carious defects were removed and access preparation was completed when the root canal filling was properly exposed Afterwards the tooth including the pulp chamber clamp and adjacent rubber dam were once again disinfected with 25 NaOCl followed by inactivation with 10 sodium thiosulfate in order to avoid interference with bacteriological sampling Sterility control samples SR1 were taken from the tooth surface with a sterile Omni Swab Whatman FTA Sigma-Aldrich with an ejectable head Paper points were transferred to cryotubes containing phosphate buffered saline PBS solution stored at -20C In each case a single root canal was sampled in order to confine the microbial evaluation to a single ecological environment In multirooted teeth the root with the periapical lesion was selected If there were periapical lesions in all roots the wider canal was selected Two of the canals included in this study were from single-rooted teeth 3 were buccal canals in maxillary premolars 1 palatal canal in maxillary molar and 10 distal canals in mandibular molars

Old root fillings were removed using Gates-Glidden drills Dentsply Maillefer Ballaigues Switzerland and endodontic files without the use of chemical solvents The working length WL was established 1-mm short of the apical foramen with an apex locator Raypex6 VDW GmbH Munich Germany and then periapical radiographs were taken to ensure that all filling material was removed Irrigation with sterile saline solution was performed in order to remove any remaining materials and to moisten the canal prior to sample collection Next the canal was left filled with saline and a small hand instrument was placed at the WL and used to gently file the canal walls An initial microbiologic sample S1 was taken from the root canal with sterile paper points consecutively placed at the WL Three sterile paper points were inserted into the root canal for sampling Each paper point was left in the canal for about 1 minute Both the paper points and the endodontic hand instrument without the handle were transferred to cryotubes containing 300 μl of PBS solution stored at -20C The samples were transferred to genetic analysis laboratory for further analysis in cold chain

Root canals were prepared by using the Revo S files and irrigated with 25 NaOCl The canals were apically enlarged to size 35 AS35 at the working length Between each instrument change the root canal was irrigated with 5 ml of 25 NaOCl solution by using 30-gauge side-vented needle which was placed 1 to 2 mm short of working length Hence a total of 30 mL of the irrigating solution was used After instrumentation was completed the smear layer was removed with 2 mL 17 EDTA which was left in the canal for 3 min followed by 25 NaOCl The root canal was dried with sterile paper points and flushed with 2 ml of 10 sodium thiosulfate for 1 min to inactivate the NaOCl solution Next a sample S2 was taken from the canals as described for S1 Following this the NaOCl was agitatedactivated as described below

XPF group The instrument XP-Endo Finisher FKG Dentaire size 25 taper 00 was cooled down Endo-Frost Roeko Langenau Germany in order to keep it straight and measure the WL The canals were flushed with 25 mL 25 NaOCl for 30 s and activated by a XPF instrument that was placed in the canal to 1 mm short of the WL and powered by the motor at 800 rpm 1 N-cm torque for 30 s according to the manufacturers instructions in slow up-and-down movements at approximately 7-mm amplitude in continuous rotation Then the canals were rinsed with 25 mL of 25 NaOCl followed by activation of the substance with the XPF instrument for 30 seconds the same way as above A new XP-endo Finisher file was used for each canal

EA group The root canals were irrigated with 25 mL of 25 NaOCl for 30 s followed by sonic activation of this solution with EndoActivator red tip size 25004 EA Dentsply Tulsa Dental Specialties Tulsa OK inserted into the root canal 1 mm short of the WL at 10000 cpmmin for 30 seconds The EA polymer tip moved vertically from apical to coronal part of the canal during activation Then the same procedure was repeated once more sonic activation of 25 mL of 25 NaOCl for 30 seconds so that the total irrigation with NaOCl and irrigation agitation time with the test devices were 1 min The total volume of NaOCl used per canal in both groups was 35 mL In both groups 5 mL of NaOCl was used and activated for one minute

Finally the canals in both groups were dried and rinsed with 2 mL 10 sodium thiosulfate for 1 min The post activation sample S3 was obtained in the same way as the pre-activation sample was collected and sent for the PCR analysis Completion of the root canal treatment proceeded with root filling using lateral condensation of gutta-percha Access cavities were restored with composite resin and a final radiograph was taken All the root canal and microbial sampling procedures were performed by a single experienced endodontist Total bacterial loads as well as the amount of Enterococcus faecalis were determined before instrumentation after instrumentation and use of the irrigation activation systems by means of droplet digital polymerase chain reaction ddPCR

Total bacterial loads as well as the amount of Enterococcus faecalis were determined before instrumentation after instrumentation and use of the intracanal medicaments by means of ddPCR

Genomic DNA isolation and measurement of DNA concentration DNA was extracted using the QIAamp DNA Mini Kit Qiagen Germany following the protocol recommended by the manufacturer Before DNA isolation samples the tubes with paper points were digested at 50-60C BY vortexING for 30s in every 10 min in order to ensure disaggregation of all bacteria into the PBS solution Afterwards the paper points were aseptically removed from the suspension and the bacterial suspension was pelleted by centrifugation for 10 min at 5000 g The pellet was then resuspended in 180 µl buffer ATL supplied by QIAamp DNA Mini Kit QIAGEN GmbH Hilden Germany and 20 µl proteinase K 20 mgml was added Samples were incubated for 3 h at 56C Subsequently total bacterial genomic DNA was isolated according to the protocol of the QIAamp DNA Mini Kit The final volume of DNA solution of each sample was 150 μL and was taken into account during calculation DNA concentration absorbance at 260 nm was determined with a spectrophotometer Promega Quantifluor

Amplification of 16S rRNA genes Primers for Universal and Enterococcus 16S rRNA genes were designed in this study After DNA extraction of samples with QIAamp DNA Mini Kit 700-800 bp of 16S rRNA sequences were amplified by using universal E8F forward primer 5-AGAGTTTGATCCTGGCTCAG-3 and universal E1115R reverse primer 5-AGGGTTGCGCTCGTTG-3 59 The final volume of PCR reactions for each isolated bacterial strain was adjusted to 25 µl The amplification reactions of 16S rRNA genes were performed with the following conditions 1 cycle of predenaturation at 95C for 3 minutes 35 cycles of 95C for 30 seconds 55C for 30 seconds and 72C for 30 seconds which continue with a final extension step at 72C for 10 minutes

The PCR products were analyzed by electrophoresis using 2 agarose gel containing ethidium bromide in TrisBoratEEDTA TBE buffer with gels being analyzed under ultraviolet light at 140V for 20 minutes Their images were visualized under ultraviolet illumination In addition the control and optimization of primers to be used for ddPCR was also done in conventional PCR

Purification and Sequencing of the 16S rRNA Gene After the PCR reactions the purification of PCR products is done by hydrolyzing the excess primers and nucleotides with ExoSap-IT Thermo PN 782011ML containing Exonuclease I and Alkaline Phosphatase enzymes 2 µl of ExoSap-IT was mixed with 5 µl of PCR product for each sample The ExoSap reaction is performed at 37 C for 15 minutes enzyme activation followed by 15 minutes inactivation at 80 C Sequencing reactions were performed by using Bigdye Terminator v31 cycle sequencing kit Thermo The reactions were performed according to the kit manual for all isolated strains

After purification of the products with Exosap the sequence reaction was performed with BigDye Terminator v31 Cycle Sequencing Kit Thermo under the following conditions After the sequence PCR BigDye products were purified by colon method Zymo ZR DNA Sequencing Clean-up Kit Zymo Research USA was used for this process All samples were purified in accordance with the protocol given in the kit and executed on the 3130XL genetic analyzer

Droplet Digital PCR ddPCR Droplet Digital PCR ddPCR was performed using primers designed according to the 16S rRNA region specific to the total bacteria and Enterococcus faecalis species after sequencing absolute quantitation from the bacterial species found in the paper-point sample Primer pairs were 16S-F-5-AGGGAATCTTCSGCAATGGG-3 and 16S-R-5-ACGCCCAATAAATCCGGACA-3 for total bacteria and ENT-F-5-CGCTTCTTTCCTCCCGAGT-3 and ENT-R-5-GCCATGCGGCATAAACTG-3 primer pairs for Enterococcus Faecalis In the PCR reaction amplicons amplified with unmarked primer pairs were analyzed by labeling with Eva-Green dye For absolute quantitation of Enterococcus and total 16S rRNA PCR was performed with two primer pairs from the same sample 20 µL of PCR mix containing 10 µL of 2X ddPCR EvaGreen Supermix Bio-Rad cat no 1864034 9 µL of nuclease-free water 025 µL of both forward and reverse primer and 2 ng of DNA from each sample Thermal cycling conditions were 95C for 5 min then 40 cycles of 95C for 30 s and 60C for 1 min and two final steps at 4C for 5 minutes and 90C for 5minutes with a 4C infinite hold After PCR was completed the sealed plate was transferred into the plate holder of the QX200 Droplet Reader Bio-Rad cat no 1864003

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None