Viewing Study NCT00514566



Ignite Creation Date: 2024-05-05 @ 6:37 PM
Last Modification Date: 2024-10-26 @ 9:35 AM
Study NCT ID: NCT00514566
Status: TERMINATED
Last Update Posted: 2007-08-10
First Post: 2007-08-08

Brief Title: PDS vs Polyamide for Midline Abdominal Closure
Sponsor: Christian Medical College and Hospital Ludhiana India
Organization: Christian Medical College and Hospital Ludhiana India

Study Overview

Official Title: Is Polydioxanone THE Suture of Choice for Midline Abdominal Closure Results of a Prospective Randomized Clinical Trial
Status: TERMINATED
Status Verified Date: 2007-08
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Unacceptable incidence of wound dehiscence in the PDS group
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: PPMAC
Brief Summary: Within the last decade the customary trend of using non absorbable sutures has changed with numerous studies and meta-analyses advocating the use of slowly absorbable sutures claiming comparable wound strength with significantly lower incidence of wound complications It was the objective of this randomized clinical trial to compare two universally accepted suture materials the non-absorbable Nylon and the slowly absorbable Polydioxanone for midline abdominal closure in the Indian context
Detailed Description: 64 patients undergoing midline laparotomy were allocated using block randomization to mass closure of the abdominal wall with continuous polyamide 34 patients or continuous polydioxanone 30 patients

There was an alarmingly higher incidence of wound dehiscence in the PDS group requiring secondary suturing Nylon 0 PDS 5 Mid-way through the trial an interim analysis was performed which revealed an unacceptably high incidence of wound dehiscence in the PDS group This necessitated a premature curtailment of the study There was however a statistically significantly higher incidence of scar pain in the Nylon group Nylon 9 PDS 1

There is a need for a study with larger series and PDS as a choice of suture for midline wound closure cannot be recommended

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None