Viewing Study NCT06835257


Ignite Creation Date: 2025-12-24 @ 6:44 PM
Ignite Modification Date: 2025-12-29 @ 9:46 PM
Study NCT ID: NCT06835257
Status: COMPLETED
Last Update Posted: 2025-02-19
First Post: 2023-08-22
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Hemodynamic Management in Autologous Blood Collection for CABG Surgery
Sponsor: Ataturk University
Organization:

Study Overview

Official Title: Evaluation of the Effect of Different Hemodynamic Managements Throughout Autologous Blood Collection Methods on Pulse Contour Analysis Parameters in Coronary Artery Bypass Graft Surgery
Status: COMPLETED
Status Verified Date: 2025-02
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: In this study, investigated the hemodynamic differences between patients who underwent acute normovolemic hemodilution during the Autologous Blood Collection procedure in coronary artery bypass graft surgery and those who did not, using hemodynamic and cardiac data obtained by MostCare's pressure recording analytical method (PRAM).
Detailed Description: Coronary artery bypass graft (CABG) surgeries are surgeries in which the need for blood transfusion is high. Allogeneic transfusion and transfusion-related complications have led researchers to use different techniques. Autologous blood collection method is one of the alternative methods used to eliminate the need for transfusion. The acute normovolemic hemodilution technique traditionally applied during autologous blood collection causes hemodilution in CABG surgeries and increases the risk of bleeding in patients. In this study, vasopressor infusion technique was used as an alternative technique to avoid hemodilution during autologous blood collection. These two techniques (Acute normovolemic hemodilution - Vasopressor infusion) applied to maintain hemodynamic stabilization during autologous blood collection were compared with the advanced cardiac and hemodynamic data provided by the pressure recording analytical method. The primary aim of the study was to compare cardiac cycle efficiency (CCE), which is a cardiac performance parameter and provides estimates of the energy spent by the cardiovascular system to maintain hemodynamic balance. Secondary objectives are to compare other advanced hemodynamic and postoperative laboratory parameters.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: