Viewing Study NCT00471913



Ignite Creation Date: 2024-05-05 @ 5:32 PM
Last Modification Date: 2024-10-26 @ 9:32 AM
Study NCT ID: NCT00471913
Status: COMPLETED
Last Update Posted: 2011-04-15
First Post: 2007-05-08

Brief Title: Functional Outcome and MRI of Muscle Damage Following Nailing Procedure in Femur Thigh Fractures Using Different Entry Points
Sponsor: University of British Columbia
Organization: University of British Columbia

Study Overview

Official Title: Functional Outcome and MR Imaging of Abductor Damage Following Antegrade Femoral Nailing With Different Entry Points A Prospective Randomized Trial
Status: COMPLETED
Status Verified Date: 2011-04
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Study focus is femoral shaft thigh bone fractures break that require surgical treatment under anaesthetic to stabilize the femur fracture This is usually done by placing a metal nail and screws inside the femur thigh bone

This study has been designed to allow us to learn more about the effect of using a different starting point to insert the nail into the body in order to access the fracture and fix it This question is important because to date all entry points currently used do result in some muscle damage In order to minimize this damage a lateral side entry nail has been developed and is currently in use at many centres This nail is new but the lateral entry technique for these types of fractures has been used extensively in the past and this nail has been developed in order to better accommodate the technique

It is believed that entering laterally instead of going deeper into the tissue to access the bone to fix it is going to result in less muscle damage which in turn will improve functional outcome
Detailed Description: Background

This study has been designed to prospectively evaluate functional outcome and MR imaging of abductor damage following antegrade femoral nailing with different entry points

Recent developments in IM nailing of the femur have favoured the use of the greater trochanter as an entry site as opposed to using the classical piriformis fossa With either technique a persistent problem appears however to be the damage caused to muscle tissue during preparation of the femur and insertion of the nail The recent development of femoral nails with an entry point lateral to both these sites offers the potential advantage of avoiding abductor muscle damage

In several cadaver studies authors state that a trochanteric entry point causes more damage than a piriformis entry and that an even more lateral entry point causes even less damage to the abductor muscles compared to the classical piriformis fossa entry site There is however no prospective clinical study has specifically evaluated the condition of the abductor tendon and the amount of muscle damage after antegrade nailing in the treatment of femoral shaft fractures The few clinical studies that have attempted to examine the functional outcome in patients undergoing IM nailing of femoral fractures have used general measurement tools general functional clinical assessment gross evaluation of gait which do not reflect the state of the art at this time and which do not specifically assess gluteal muscle condition To date no published study has evaluated the integrity of the gluteus tendon the damage to the surrounding tissues and the functional outcome using validated scores Moreover no study has compared the traditional entry points to a lateral entry nail with this level of precision

The standard of care for the treatment of femoral shaft fractures is the insertion of an intramedullary nail through the piriformis fossa Following insertion of femoral IM nails a number of studies have demonstrated excellent clinical and radiographic results with relatively few complications such as nonunion malunion or infection Intraoperative difficulties with respect to rapid identification of the appropriate starting point have prompted the development of nails that use the greater trochanter as an entry site as opposed to using the classical piriformis fossa

As stated earlier with either technique a persistent problem appears however to be the damage caused to muscle tissue during preparation of the femur and insertion of the nail The recent development of femoral nails with an entry point lateral to both these sites offers the theoretical advantage of avoiding abductor muscle damage There is so far a lack of prospective randomized trials which demonstrate radiological and clinical parameters of the different entry points

Objective To determine the abductor tendon and muscle damage with MR-imaging according to the entry point of the femoral nail Additionally objective hip muscle function general health status and functional outcome will be assessed using validated instruments

We aim to correlate muscle damage due to the different entry points and correlate with the functional outcome Further to quantify the differences advantages of different IM nailing techniques of the femur with respect to effect on the abductor musculature muscle testing and gait and patient-based functional outcome to guide surgeons decisions and future research

Recent Related Work In a recently published report by Ricci et al the use of the trochanteric entry point was associated with a low complication rate and good clinical results including the assessment of a gait video In this admittedly small prospective study the superiority of either the trochanteric or the piriformis fossa entry point nail could not be established Although gait was evaluated video in 30 of the study population this was limited to a subjective assessment of the presence of a Trendelenberg gait absent slight or present There was no statement about the muscle status and functional outcome assessment was limited to a Harris Hip Score

Abductor tendon condition and muscle damage has previously been assessed with MR-imaging by the group of Pfirrmann et al in patients with total hip arthroplasty through a transgluteal approach This study showed a high correlation between damage and clinical outcome

The co-applicants research group has previously carried out many clinical studies including its part in a multi-centre randomized trial in femur fractures It also specifically has carried out a functional assessment of patients following femur fractures which included objective muscle testing of isokinetic force using a KinCom dynamometer formal gait lab analysis using an eight camera real-time motion capture system in conjunction with a force-plate walking platform and as part of the same study the administration of validated self-assessment outcome questionnaires

So far no prospective randomized trial has investigated as we have planned to do the radiological MR functional and clinical outcome after insertion of a femoral nail through two different entry points

Method Patients will be assigned randomly via computer generated randomization to one of two groups The two groups will undergo standard treatment of IM nailing for the femoral shaft fracture differing only in entry point of the nail piriformis fossa entry point versus lateral entry point

Design Patients between 19 and 60 years of age presenting with an isolated femoral shaft fracture that requires IM nailing will be asked to participate in this study Informed consent for participation in the study will be obtained by either a member of the health care team or by a research nurse

Consenting patients who meet the inclusion criteria will be randomized to either piriformis fossa or lateral entry femoral nailing Preoperative Intraoperative and follow-up data will be obtained Data will detail clinical assessment MRI results objective muscle testing and gait analysis

Power analysis In a published report from Pfirrmann et al distinct conclusions could be made in a collective of 54 patients We plan to recruit 60 patients 30 per group with a projected drop-out rate of 10 As this is a pilot study without previous reference a similarity in expected findings and required sample size must be inferred Cases will be randomized using a web-based allocation tool

Outcome Variables

Variables for collection and analysis are

1 Preoperative

i Demographics ii ISS Injury Severity Score iii AO Fracture Classification
2 Intraoperative

i Elapsed time from injury to operative treatment ii Fluoroscopy time iii Incision length iv Blood loss
3 Postoperative

i VAS pain scores ii Morphine requirements q 24hrs iii Change in hemoglobin q 24hrs iv Hospital Length of Stay v Clinical and Radiological follow-up at 3 6 9 and 12 months vi MRI at 12 months vii Self-administered validated outcome tools at 6 and 12 months SF-36 SMFA Harris Hip Score Merle dAubigne score although last two are not validated they would allow for comparison with widely published scores in established literature

Study Specific Measures

Postoperative follow-up

All patients will be reviewed clinically in the fracture clinic at two six twelve weeks and six and twelve months postoperatively Study data will be acquired at the six and 12 month appointments

Clinical assessment

Bilateral measurements will be recorded so that the results from the unaffected limb are used as a control for the injured limb Both the raw data and the side to side differences will be used in the analysis Physical examination to document any limb length discrepancy Trendelenberg sign rotational malalignment and the ranges of motion of the hip and knee

Questionnaires

A study specific questionnaire will be administered to determine the extent and location of any persistent pain in the affected limb ability to return to their usual occupation and recreational activities

Functional outcome scores SF-36 SMFA Harris Hip Score Merle dAubigne score will be collected at 6 and 12 months All of these outcomes tools are widely referenced in the literature and can be used for comparison purposes

MR Imaging

An MRI will be administered at 12 months and will include evaluation of abductor tendon defects diameter signal intensity ossification and bursal fluid collections The abductor muscles will be evaluated by MRI for fatty atrophy

Muscle strength testing and gait analysis

Muscle strength testing will take place at 12 months and will utilize the KinCom Dynamometer a widely used standard research protocol and specifically-designed instrument for use in muscle strength testing to evaluate muscle strength Peak isokinetic force measurement maximum strength nmkg and work Jmin of hip abductors hip extensors and knee extensors

Gait analysis will take place at 12 months and will employ a standard eight camera real-time motion capture system in conjunction with a force-plate walking platform to collect and evaluate pelvic obliquity hip abductor movement single leg support time and step length

Data Analysis

The side-to-side differences will be summarized and compared across treatment groups Additionally aggregated raw data by treatment group will be summarized and compared using t-test for the comparison of continuous variables means and Chi-square for categorical data

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None