Viewing Study NCT04900077



Ignite Creation Date: 2024-05-06 @ 4:11 PM
Last Modification Date: 2024-10-26 @ 2:05 PM
Study NCT ID: NCT04900077
Status: COMPLETED
Last Update Posted: 2022-04-05
First Post: 2021-05-05

Brief Title: Effect of Carriere Motion Appliance on Airway Dimensions
Sponsor: King Abdulaziz University
Organization: King Abdulaziz University

Study Overview

Official Title: Short Term Effect of Carriere Motion Appliance on Pharyngeal Airway Dimensions A Prospective Controlled Clinical Study
Status: COMPLETED
Status Verified Date: 2022-03
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Objectives to evaluate the effect of treatment with Carriere Motion Appliance on pharyngeal airway skeletal and dental dimensions using lateral cephalometric radiographs and to compare these changes with a control group

Materials and Methods a prospective controlled clinical study on 17 patients treated at King Abdulaziz university dental hospital Jeddah Saudi Arabia with a mean age of 1525 249 years with class II molar relationship treatment group They were treated with Carriere Motion Appliance and initial and post treatment lateral cephalograms were taken to assess the effect of the appliance on the pharyngeal airway dimensions skeletal and dental measurements A matched sample of 18 untreated patients with a mean age of 1444 225 years acted as a control group Independent sample T-test and paired T-tests were conducted The significance level was set at P 005

Results when the cephalometric changes associated with the treatment by Carriere Motion Appliance were compared to the changes in the untreated control group no significant differences were found between the groups in regard to the pharyngeal airway and the skeletal dimensions The only significant difference between the two groups was in the proclination and the protrusion of the lower incisors The treatment group showed significantly increased lower incisors proclination and protrusion L1 to mand plane 33826 L1-Apo 099145 compared to the control group L1 to mand plane049281 L1-Apo039186 P005

Conclusion treatment with Carriere Motion Appliance does not have a significant effect on pharyngeal airway and skeletal dimensions However it significantly increases the lower incisors proclination and protrusion
Detailed Description: None

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: True
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: True
Is an FDA AA801 Violation?: None
Secondary IDs
Secondary ID Type Domain Link
1532-165-1440 OTHER_GRANT King Abdulaziz University Research Grants None