Viewing Study NCT01826968


Ignite Creation Date: 2025-12-24 @ 5:34 PM
Ignite Modification Date: 2026-01-01 @ 6:31 PM
Study NCT ID: NCT01826968
Status: COMPLETED
Last Update Posted: 2015-06-23
First Post: 2013-03-29
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Alveolar Recruitment Maneuver During Cesarean Section Improves Lung Compliance
Sponsor: General Hospital Of Pyrgos
Organization:

Study Overview

Official Title: Phase 2 Study of the Alveolar Recruitment Maneuver in Cesarean Section
Status: COMPLETED
Status Verified Date: 2013-11
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: CSRecGHPyr
Brief Summary: The investigators tested the hypothesis that alveolar recruitment maneuver during cesarean section and in women under general anesthesia improves lung compliance and gas exchange. The investigators applied recruitment maneuver and positive end expiratory pressure (PEEP) 8 cmH2O. The maximum alveolar pressure limit (Ppeak)was 45 cmH2O during the recruitment maneuver. The primary end point of the study is the improvement of the lung compliance measured as volume difference/pressure difference (dv/dp) or ml/cmH2O
Detailed Description: The investigators used recruitment maneuver during cesarean section and in women under general anesthesia. The primary end point of the study is the improvement of the lung compliance measured as volume difference/pressure difference (dv/dp) or ml/cmH2O after the recruitment maneuver. The investigators used 2 groups of patients. In the first group the investigators used pressure control ventilation for the recruitment maneuver. After the ventilator was switched to pressure control mode the investigators increased the inspiratory time to 50% and the inspiratory pressure above Positive End Expiratory Pressure (Ppeak) to 20 cmH2O. Then the investigators progressively increased Positive End Expiratory Pressure (PEEP) to have a peak inspiratory pressure (Ppeak) to 45 cm H2O. The whole recruitment maneuver lasts 2 minutes. After the recruitment maneuver the investigators used volume control ventilation again (with the baseline settings)and PEEP step wised decreased to 8 cmH20but. PEEP (8cmH2O) was left until the end of the operation. In the second group the investigators did not used lung recruitment maneuver at all. In both groups lung compliance was measured (dynamic and static)as dv/dp (ml/cmH2O). Measures were assessed 1 minute after delivery (but before recruitment), 3 minutes after recruitment (first group) at 10 and at 20 minutes after recruitment. The investigators also measured Ppeak (cmH2O) and Pplateau (cmH2O)inspiratory pressures , blood pressure (mmHG), beats per minute, oxygen saturation, end-tidal CO2 according to the above time frame, blood Gases before and 3 minutes after recruitment etc.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?:

Secondary ID Infos

Secondary ID Type Domain Link View
GHPyrgosRECProt OTHER RECProt010113 View