Viewing Study NCT00405483



Ignite Creation Date: 2024-05-05 @ 5:10 PM
Last Modification Date: 2024-10-26 @ 9:29 AM
Study NCT ID: NCT00405483
Status: UNKNOWN
Last Update Posted: 2019-02-08
First Post: 2006-11-28

Brief Title: RSA for a Comparison of MIS vs Standard Exposure in Total Hip Arthroplasty
Sponsor: Dalhousie University
Organization: Dalhousie University

Study Overview

Official Title: A Randomized Controlled Trial Utilizing RSA for a Comparison of Minimally Invasive Surgery MIS vs Standard Exposure in Primary Total Hip Arthroplasty With the ProfemurZ Modular Femoral Stem
Status: UNKNOWN
Status Verified Date: 2019-01
Last Known Status: ACTIVE_NOT_RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The purpose of this study is to determine if MIS for primary hip replacement surgery increases the risk of long term aseptic loosening as predicted by implant micromotion detected by radiostereometric analysis
Detailed Description: Hip replacement is an effective option for treating chronic hip conditions that cause pain and functional impairment1 Significant improvements in quality of life as measured by both disease specific and generic quality of life measures have been well documented 2-4

Hip replacement implants are a ball in cup design and consist of two articulating components a femoral head replacement which can consist of a ball attached to a stem that is inserted into the proximal femur and an acetabular component which can be made of different materials that are inserted into a liner of metal that is inserted into the pelvis These components can be attached to the patients bone using either polymethylmethacrylate - a polymer more commonly referred to as bone cement - or by roughening the surface of the implant to allow bone ingrowth Hip replacements can therefore be broadly classified by the fixation technique used cemented uncemented or hybrid consisting of a cemented femoral component and an uncemented acetabular component The uncemented design is very commonly used in younger patients because the quality of bone is better in the patient the implants have demonstrated long term survival and the cementing step is no longer necessary for achieving long term fixation

The 10 year survival of current uncemented total hip designs approaches 95 5 The majority of the 5 that are revised are done so for aseptic non-infected loosening of the components The functional results of revision total hip surgery are poorer than primary hip replacement surgery 3 5 6 There are approximately 20 000 hip replacement performed each year in Canada CIHI website this will result in roughly 1000 revisions over the next 10 years - a great expense both in terms of health care resources and in patients loss of function Obviously efforts directed at decreasing revision rates are clinically and financially worthwhile

Implant failure due to aseptic loosening is thought to arise from both patient related factors such as age sex and diagnosis and from implant related factors such as design and materials used 5 Efforts at reducing aseptic loosening by changing implant design and cement formulation have occasionally resulted in products that perform well in the laboratory but fail miserably in real life often after being implanted into large numbers of patients7-10 This has led to a call for careful and controlled introduction of new implant designs using randomized trials and precise radiographic assessment techniques such as radiostereometric analysis RSA to look for early signs of loosening and impending failure 7 9 11

Minimally Invasive Surgery MIS is a new technology in the optimization of healthcare services It has been developed to minimize damage to surrounding tissue during arthroplasty by reducing the size of the incision The possible benefit is dramatic reductions in length of stay LOS for total hip replacement THR patients 12 However MIS development has led to modifications to existing instrumentation prostheses and technique which may impact long-term survival of the implant 13 There has been little research investigating the effects of these changes on long-term patient outcomes following MIS surgery The use of RSA will allow for better understanding of the early fixation of the implant and the potential for early failure due to aseptic loosening

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None