Viewing Study NCT04248868


Ignite Creation Date: 2025-12-24 @ 5:30 PM
Ignite Modification Date: 2025-12-28 @ 7:06 AM
Study NCT ID: NCT04248868
Status: COMPLETED
Last Update Posted: 2023-04-20
First Post: 2020-01-28
Is NOT Gene Therapy: True
Has Adverse Events: True

Brief Title: tPA by Endovascular Administration for the Treatment of Submassive PE Using CDT for the Reduction of Thrombus Burden
Sponsor: Thrombolex, Inc.
Organization:

Study Overview

Official Title: Recombinant tPA by Endovascular Administration for the Treatment of Submassive Pulmonary Embolism Using Pharmaco-mechanical Catheter Directed Thrombolysis for the redUction of Thrombus burdEn
Status: COMPLETED
Status Verified Date: 2023-03
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: RESCUE
Brief Summary: To demonstrate the efficacy and safety of the Bashir™ Endovascular Catheter for the administration of pharmaco-mechanical catheter directed therapy using low dose r-tPA for the treatment of acute submassive pulmonary embolism.
Detailed Description: The Bashir™ Endovascular Catheter has been designed to administer therapeutic agents in the peripheral vasculature. Because of the unique design of the catheter, with its six expandable infusion limbs, the Bashir™ Endovascular Catheter has the ability to: 1. Create a much larger central channel for blood flow, thereby utilizing the body's own endogenous fibrinolytic agents to lyse the clot, and 2. Greatly enhance the radial dispersion of a catheter-administered thrombolytic agent throughout the thrombus. Expansion of the multiple arms of the basket in the infusion catheter causes fissuring of the clot. The net result is that a greater surface area of clot is exposed to both endogenous and exogenously administered lytic agents, thereby promoting clot dissolution.

This study will utilize the Bashir™ Endovascular Catheter and the Bashir Endovascular Catheter with a short basket (BASHIR™ S-B endovascular catheter) to administer catheter directed thrombolysis in patients with submassive PE who have consented and meet all eligibility criteria. The Bashir™ and BASHIR™ S-B endovascular catheters represent a new methodology for localized catheter-based delivery of thrombolytics. The thrombolytic to be used in this study is r-tPA (Genentech Corporation, South San Francisco, USA).

The design of the Bashir Endovascular Catheter with the multiple infusion limbs creating a basket-like formation when expanded, provides an immediate channel for blood flow through the thrombus and a greater surface area in the thrombus for the endogenous and exogenous thrombolytics to take effect, as described above.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: True
Is a FDA Regulated Device?: True
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: