Viewing Study NCT03846037



Ignite Creation Date: 2024-05-06 @ 12:46 PM
Last Modification Date: 2024-10-26 @ 1:04 PM
Study NCT ID: NCT03846037
Status: COMPLETED
Last Update Posted: 2019-02-19
First Post: 2019-02-11

Brief Title: Evaluation of the Balance Muscular Electric Activity Proprioception Before and After in the Vibratory Platform
Sponsor: Universidade do Vale do Paraíba
Organization: Universidade do Vale do Paraíba

Study Overview

Official Title: Effects of Proprioceptive Exercises Associated With Vibratory Stimuli on Electromyographic Activity Postural Oscillation and Sense of Joint Position in Healthy Individuals
Status: COMPLETED
Status Verified Date: 2019-02
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Introduction Proprioception refers to the informations dynamic sent to central nervous system by the free nerve endings and mechanoreceptors about the biomechanics relationship for the joint tissue The proprioceptive exercises show a big prophylactic action by musculoskeletal injuries Among the top modalities of these exercises it can be cited the Whole Body Vibration WBV Objectives The objective of this study was to evaluate and compare the joint position sense muscle electric activity and the postural sway in healthy individuals before and after performing proprioceptive exercises on the vibrational platform or on a stable surface Materials and Methods 20 healthy young 2485 427 years were recruited randomly divided into two groups Control Group GC and Experimental Group GE Were realized evaluates of the proprioception by means of the joint position sense the muscle electric activity of peroneus longus gastrocnemius medialis vastus medialis and gluteus medium and the postural sway by means of the postural sway before and after one assistance consisting of 4 sets of 60s with unipodal standing position on soil GC or on vibrational platform GE
Detailed Description: The individuals who composed the two groups performed the same exercise protocol however on different surfaces

Control group stable surface
Experimental group - vibratory platform make model Nissan Fisio orbital amplitude 6 mm frequency 30 Hz The exercises consisted of unipodal support on the non-dominant lower limb with the contralateral limb in a knee flexion near 90º This exercise is a proprioceptive test that requires more than all joints and musculature of the lower limb and is widely used in studies for providing obvious clinical signs in the presence of dysfunctions

Activities were performed with the individual standing without using any type of footwear remaining without support of the hands and with the upper limbs abducted to 90º with the fixed eye on the horizon line Both groups performed 4 sets of 60s of sustained posture In the intervals between the series there was the rest of 60s remaining in orthostasis with support of the upper limbs

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None