Viewing Study NCT01841866


Ignite Creation Date: 2025-12-24 @ 4:26 PM
Ignite Modification Date: 2026-01-02 @ 6:54 AM
Study NCT ID: NCT01841866
Status: UNKNOWN
Last Update Posted: 2019-07-31
First Post: 2013-04-24
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Laryngeal Mask Airway Removal During Deep Anesthesia in Children
Sponsor: Prince of Songkla University
Organization:

Study Overview

Official Title: Does Laryngeal Mask Airway Removal During Deep Anesthesia Reduce Postoperative Sore Throat in Children?
Status: UNKNOWN
Status Verified Date: 2019-07
Last Known Status: RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Laryngeal mask airway (LMA) is widely used in children.The appropriate time to remove laryngeal mask airway is still inconclusive.Sore throat is one of common complications after general anesthesia. Sometimes postoperative sore throat affects patients' satisfaction and daily activities. It can be correlated with dysphagia and may limit oral intake especially in children.The incidence of postoperative sore throat after laryngeal mask airway insertion varies from 5.8-34% in adult(13) and 17.5% in pediatric.Somehow, almost the studies of postoperative sore throat after laryngeal mask airway removal were done in awake state. Our study object to test that post operative sore throat after LMA removal in deep anesthetized children is lower than awake children.
Detailed Description: Patients age between 6-12 years who have ASA physical status I-II and scheduled for elective surgery will be enrolled in this study and randomly assigned into two groups (group A = awake group and group D = deep anesthetized group) by using computer-generated randomization table. The patients who have the following problems: active airway disease, risk of aspiration, intra-peritoneal or airway surgery will be excluded.

At the day of surgery, demographic data will be recorded by nurse anesthetist. Visual analog scale (VAS) will be used as a tool for evaluating preoperative sore throat.

At the operating room, after standard monitoring and pre-oxygenated with 100% oxygen via tight anesthetic face mask for 5 minutes. Propofol (3-5 mg/kg) and fentanyl(1-3 ug/kg) will be used for induction. After the patient is apnea and loss of eyelash reflex, appropriate size of classic LMA ,which is prepared by fully deflated to forms a smooth "spoon-shape" and be lubricated by water based jelly, will be applied with standard LMA insertion technique. Once LMA is in the right position, air will be inflated to the cuff of LMA, for keeping cuff pressure between 40-60 cmH2O. Air, O2 and Sevoflurane ≥ 1minimal alveolar concentration (MAC) will be used to keep the patient anesthetized. Performer of LMA insertion and number of insertion attempts will be recorded.

At the end of surgery, LMA will be removed with the technique which is followed by the group assignment, group D and group A. After that, patient will be transferred to post anesthetic care unit (PACU).

At PACU, After the patient is fully awake, the blind investigator will ask the patient to evaluate post operative sorethroat by using Visual analog scale (VAS) (0-10). Dysphagia (discomfort when swallowing) using dysphagia score (0 = able to eat normal diet / no dysphagia, 1 = able to swallow some solid foods, 2 = able to swallow only semi solid foods, 3 = able to swallow liquids only, 4 = unable to swallow anything / total dysphagia), dysphonia (discomfort when speaking such as hoarseness) using dysphonia score (0 = no hoarseness, 1 = mild/no hoarseness in the time of interview but had it previously, 2 = moderate/only is felt by the patient or their parents, 3 = severe/recognizable in the time of interview) Any adverse events will be evaluated at 1 hour in PACU. Then the evaluation will be repeated by telephoned interview at 24 and 72 hours respectively.

Study Oversight

Has Oversight DMC: True
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: