Viewing Study NCT03180060



Ignite Creation Date: 2024-05-06 @ 10:09 AM
Last Modification Date: 2024-10-26 @ 12:25 PM
Study NCT ID: NCT03180060
Status: COMPLETED
Last Update Posted: 2017-06-08
First Post: 2017-06-06

Brief Title: Meta-Analysis of Stress Myocardial Perfusion Imaging
Sponsor: American British Cowdray Medical Center
Organization: American British Cowdray Medical Center

Study Overview

Official Title: Accuracy and Heterogeneity of Stress Imaging for Detecting Coronary Artery Disease A Systematic Review and Meta-Analysis Using HSROC Methods in 23051 Patients
Status: COMPLETED
Status Verified Date: 2017-06
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Background Detection of coronary artery disease CAD is important due to its high prevalence and its medical and economic implications Purpose A systematic review of the diagnostic performance of stress echocardiography Echo SPECT cardiac magnetic resonance CMR CT Perfusion CTP and PET versus invasive coronary angiography ICA or fractional flow reserve FFR using hierarchical summary ROC HSROC methods Data Sources MEDLINE EMBASE and SCOPUS for literature published in English or Spanish from January 1970 to December 2015 Study Selection For inclusion studies had to meet the Cochrane guidelines had to evaluate the sensitivity and specificity methods and use ICA andor FFR Only those studies with STARD methodology 60 were included Data Extraction Ten investigators extracted patient and study characteristics and 4 resolved any disagreements
Detailed Description: Review question What non-invasive cardiovascular imaging tests SPECT Stress Echo SE Cardiovascular Magnetic Resonance CMR CT Perfusion CTP and PET myocardial perfusion have the best diagnostic accuracy to detect obstructive coronary artery disease using four different cutoffs two anatomic invasive coronary angiography and two functional invasive fractional flow reserve Which non-invasive cardiovascular imaging tests SPECT Stress Echo CMR CTP and PET myocardial perfusion have the least bias and heterogeneity in their published data

Searches Search in MEDLINE EMBASE and SCOPUS databases for the literature published in English or Spanish from January 1970 to December 2015 of all prospective and retrospective studies performed with Stress Echo SPECT PET CMR and CTP in patients with suspicion or known CAD compared against the reference standard of ICA two cutoffs lesions 50 and 70 andor invasive FFR two cutoffs 080 and 075

Condition being studied Obstructive coronary artery disease Non-invasive imaging modalities SPECT Stress Echo CMR CTP and PET to evaluate myocardial perfusion as indicative of obstructive coronary artery disease

Intervention There was no intervention or exposure since it was an evaluation of diagnostic accuracy of worldwide current non-invasive cardiovascular imaging modalities compared to the accepted standard of reference

Comparator No control group used

Context Studies in English and Spanish were included to avoid missing any relevant high quality contributions in different languages Other languages different from English and Spanish were not included due to language barriers and limitations regarding understanding the full text document and to obtaining the necessary data since those papers generally only have the abstract in English There were no restrictions in country of origin type of technique or equipment used since we made performed a sub-analysis for those minor variables not reported in all papers

Data extraction After study planning we decided to decided to included all published studies and decided not to include data that hadnt been formally published Our search strategy with three terms related to the research question considering patient population intervention types of the different imaging modalities and the design type we decided to include two types of search terms free words and standardized words such as those use in Medical Subject Headings MeSH for PubMed and for EMBASE we used EMTREE terms we also used a combination of thematic terms selected by a controlled vocabulary the Thesaurus open when necessary and with broad range of free text terms As we described in detail as follows the data extraction was always with more than two researchers The team was divided into a searcher a search advisor and five junior and four senior reviewers Four senior reviewers gathered together to define the MeSH terms necessary for the literature search The searcher and the search advisor one senior reviewer worked together to build up the corresponding search algorithms as follows for prospective or retrospective clinical trials case series abstracts and gray literature in English or Spanish for PubMed for EMBASE and for Scopus also for meta-analysis and systemic reviews for PubMed for EMBASE and for Scopus for the period comprised between January 1970 to December 2015 One senior author first author was designed as administrator then all retrievals from the searcher went directly and only to the administrator to avoid duplications or gaps in the review process First the administrator received a search with titles and abstracts which she distributed equally to the four senior reviewers including the administrator to make an initial selection and to eliminate all titles and abstracts that did not meet the inclusion or exclusion criteria which was then gathered together by the administrator and sent back to the searcher whose used the list of selected documents titles and abstracts to send a second package of searches to the administrator with all documents in full text version who again equally distributed these documents to all four senior reviewers who then validated the inclusion and exclusion criteria which may have been missed in the abstract alone the resulting package was again returned to the administrator who equally distributed the documents to all junior and senior reviewers to score each study according to the STARD checklist for this type of project We previously established a minimum of 60 of points in the STARD checklist for a study to be approved and be included in the next stage of the review All scoring sheets were sent back to the administrator within the timeline period All disagreements were solved during our research meetings by a consensus of the senior reviewers The administrator then selected the studies to be included in the meta-analysis based on the STARD score and distributed them equally to all junior and senior reviewers including the administrator to extract data in a pre- designed data capture sheet At the deadline the administrator gathered together all data capture sheets and then re-distributed equally with the original papers to the four senior reviewers who did a second review of each study to assure quality of the extracted data All disagreements were solved during extra research meetings of the senior reviewers by consensus After the data were accepted by the four senior reviewers the administrator provided another senior reviewer acting as a statistician with all captured data to start the statistical analysis At the same time all studies included in the meta-analysis were again distributed by the administrator to two senior reviewers the administrator and the statistician who did the data extraction for the sub-analysis each senior reviewer took two imaging modalities for review and after completion those sub-analysis data were gather together by the statistician to be included in the meta-analysis

Risk of bias In the selection process bias risk was managed by using a double check of the selection criteria by senior reviewers by scoring each study by STARD methodology using its checklist and a rigid criteria of 60 to be considered for further analysis any disagreements between the junior and senior review authors over the risk of bias in particular studies were solved by discussion during an extra research meeting of two senior authors with involvement of a third reviewer when necessary The publication bias was evaluated in graphic manner using Funnel plots and in mathematical form with Begg and Egger tests A value of p005 was defined as significant

Strategy for data synthesis We performed Forrest plots for each test and HSROC curves with the Moses-Littenberg method We calculated AUC and Q for each test Total values of sensitivity specificity DOR LR and LR- as well as 95 CI were calculated using the bivariate model of Teitsma and the models of HSROC hierarchical summary ROC of Rutter and Gatsonis The differences between the tests were evaluated using meta-regression comparing different models with the likelihood ratio test The analysis of heterogeneity between studies was evaluated in graphic form in the HSROC curves and in mathematical manner with meta-regression and the calculation of Higgins I2 this last test Higgins I2 was not reported within the results since in diagnostic test accuracy studies this I2 statistic alone may not be informative as they do not consider threshold effect in comparison to this same statistical test when it is used for the analysis of heterogeneity between therapeutic and or interventional studies since a threshold effect can be considered In our study the publication bias was evaluated in graphic manner using Funnel plots and in mathematical form with Begg and Egger tests A value of p005 was defined as significant

Analysis of subgroups To analyze statistical differences in diagnostic accuracy between modalities we based the analyses on mathematical combinations and used the term certainty to refer to diagnostic accuracy that one imaging modality has over the other one then we performed the meta-regression analysis for comparison of certainty between two imaging modalities at the same time We used a graphic representation for the results We did a post-hoc analysis by sub-groups to all other variables common to every technique andor specific for each imaging modality studied

Dissemination plans A paper will be submitted to a leading journal in this field The findings of the review produced solid evidence that can change current worldwide practice for the benefit of patients institutions and public health services by obtaining higher accuracy in the diagnosis of significant coronary artery disease in terms of myocardial ischemia thus avoiding extra unnecessary tests less harm to the patients and less unnecessary expenses

Current review status Completed but not published

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None