Viewing Study NCT02614924



Ignite Creation Date: 2024-05-06 @ 7:52 AM
Last Modification Date: 2024-10-26 @ 11:53 AM
Study NCT ID: NCT02614924
Status: COMPLETED
Last Update Posted: 2016-08-22
First Post: 2015-11-24

Brief Title: Comparison of Flexible Fibreoptic Scope With Pentax AWS Videolaryngoscope for Ease of Intubation During Awake Intubation
Sponsor: University Hospitals Coventry and Warwickshire NHS Trust
Organization: University Hospitals Coventry and Warwickshire NHS Trust

Study Overview

Official Title: Comparison of Flexible Fibreoptic Scope With Pentax AWS Videolaryngoscope for Ease of Intubation During Awake Intubation
Status: COMPLETED
Status Verified Date: 2016-07
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The purpose of this study is to identify whether Pentax Airway Scope AWS videolaryngoscope would be a more effective device compared to flexible fibreoptic scope FOS for awake intubation in a difficult airway
Detailed Description: Background

The incidence of difficult tracheal intubation during routine anaesthesia in general population is around 3-18 although it varies 1 Awake intubation is considered in situations such as in patients with a known or suspected difficult airway upper airway obstruction Awake intubation under local anaesthesia and sedation also indicated cervical spine disease in view of minimising movement of cervical spine 2 Any technique tracheal intubation under general anaesthesia involves some degree of movement at cervical spine Direct laryngoscopy and tracheal intubation in under general anaesthesia is usually achieved by flexion of lower cervical spine and extension at atlanto-occipital joint 3 Difficulties or failure in airway management is still an important factor in morbidity and mortality related to anaesthesia

In recent years videolaryngoscopes have been used as an alternative to traditional fibreoptic scope in the management of difficult airway 478 Over last 2 years in our institution the investigators have used Pentax AWS videolaryngoscope for awake intubation in patients presenting for surgery with cervical spine disease 9 10

However there has not been any study comparing flexible fibreoptic scope with video laryngoscopes in the management of difficult airway in awake patients The proposed benefits of Pentax AWS Airway scope over a flexible fibreoptic scope include ease of setting up the device less complexity of the skill therefore easy to learn the skill and availability of disposable devices minimising the need for cleaning and disinfecting the device

Pentax AWS with PBlade videolaryngoscope has a unique target symbol displayed on the monitor which highlights the intended path of the endotracheal tube The Pentax PBlade is a single patient use device that minimizes the risk of infection

Study Design and Methods Randomised Controlled Trial

Patient Selection

Forty patients presenting for cervical spine surgery under general anaesthesia and requiring oral endotracheal intubation will be invited to take part in the study During preoperative visit a patient information sheet will be given to the patients meeting the eligible criteria The patient will be given adequate time to read the information sheet and any queries will be answered Wherever possible suitable patients will be identified in the preoperative assessment clinic A detailed airway assessment will be performed by one of the investigator

Whenever possible when patients are admitted the night before their operation they should be seen by an Anaesthetist and given the study information

Techniques of Anaesthesia

After securing intravenous cannulation and instituting standard anaesthetic monitoring with ECG pulse oximetry and non-invasive blood pressure monitoring conscious sedation will be started using target controlled infusion of remifentanil and 1 mg of midazolam At this stage numbered opaque envelope will be opened to choose one of the two devices The tongue oropharynx and larynx will be anaesthetised using 4 lignocaine using Mckenzie technique nebulisation of local anaesthetic through 20 G cannula

Adequate anaesthesia of upper airway will be checked by inserting an appropriately sized oropharyngeal airway if the patient can tolerate well the airway is anesthetised adequately if not further local anaesthetic is administered to the oropharynx After confirming adequate anaesthesia of upper airway the chosen device will be inserted into the oropharynx Further local anaesthesia to the base of the tongue larynx and trachea will be administered using spray as you go technique where the local anaesthetic administered through the device whilst gradually advancing the device towards larynx After confirming the position of the tracheal tube and testing the gross neurological state of all 4 limbs general anaesthesia will be induced

Data Collection

During the procedure of laryngoscopy and endotracheal intubation a modified intubation difficulty score IDS would be developed based on the parameter recorded Along with intubation difficulty score other parameters compared include time taken to complete the process of intubation anaesthetist rating of intubation and patient rating of procedure

The following parameter would be recorded and scored

1 Coughing episode 0 no cough 1 if mild cough 2 if moderate cough 3 if severe cough
2 Gagging episode 0 no gagging 1 if mild gag 2 if moderate gag 3 if severe gag
3 Ease of insertion of device 0 easy 1 if mild difficulty 2 if moderately difficulty 3 very difficult
4 Laryngoscope view based on the percentage of the glottis visualised 0 if 75-100 view 1 if 50-75 view 2 if 50 view 3 no VC visible
5 Tube rotation or manipulation 0 if no rotation required 1 if rotation required
6 Airway trauma 0 no trauma 1 if minor injury lip 2 if oro-pharyngeal injury bleeding 3 bleeding requiring use of suction
7 Stress response based on heart rate and blood pressure 0 if stable 1 if increased more than 20
8 Overall patients tolerance as judged by the Anaesthetists visual analogue score of 0 to 100mm
9 Overall impression from patient on a visual analogue scale visual analogue score of 0 to 100mm

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None