Viewing Study NCT07386067


Ignite Creation Date: 2026-03-26 @ 3:18 PM
Ignite Modification Date: 2026-04-06 @ 2:42 AM
Study NCT ID: NCT07386067
Status: COMPLETED
Last Update Posted: 2026-02-04
First Post: 2026-01-27
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Mesh Design for Open Inguinal Hernia
Sponsor: Zagazig University
Organization:

Study Overview

Official Title: Mesh Design for Open Inguinal Hernia Repair: Superior Outcomes and Fewer Complications
Status: COMPLETED
Status Verified Date: 2026-01
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Inguinal hernia repair is the most common operation performed by general surgeons worldwide, surgical repair is the only established definitive treatment for inguinal hernia with multiple variable described approaches, Since Lichtenstein and his colleagues pronounced the use of mesh in tension-free inguinal hernia repair, the open Lichtenstein mesh repair of inguinal hernia became a standard of care for inguinal hernia repair due to easiness of performance with low recurrence rates (1, 2, 3).

In the past many different factors have been identified to reduce chronic postoperative inguinal pain CPIP, Sophisticated studies suggested that mechanical mesh fixation should be avoided, and proper knowledge of inguinal nerves is essential (4-9).

Surgeons must consider patient characteristics and mesh properties when selecting a mesh for hernia treatment. Mechanical compatibility between meshes and abdominal wall layers is crucial for avoiding complications. Lightweight, monofilament meshes with large pores and minimal surface area are ideal; however, the surgeon should never forget that the way the mesh is positioned as important as the type of mesh used. Despite the new materials available, surgical skill still has a major role in preventing hernia post-operative complications and recurrence. Future research will continue to focus on the surgical techniques and biomaterials to achieve the best outcomes (10).

Our method uses a smaller single mesh that covers all weaknesses in the inguinal canal and is covered with a fibro-cremasteric sheath to prevent the prosthesis from coming into touch with neural processes. This method is applicable to all cases of primary inguinal hernia.
Detailed Description: None

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: