Brief Title: Quality Assessment Creatinines in Plasma and Urine
Sponsor: Medical Research Foundation, The Netherlands
Organization:

Study Overview

Official Title: Quality Assessment of Creatinines in Plasma and Urine
Status: COMPLETED
Status Verified Date: 2012-04
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: In clinical practice the 24-hour creatinine clearance is often used to obtain an impression of renal function. However, the glomerular filtration rate is considered to be the best indicator of renal function. For practical and financial purposes, GFR is often estimated by means of serum creatinine based equations. These equations are also used in internation guidelines to define and classify chronic kidney disease. Therefore, accurate creatinine measurements are important to make reliable estimates of renal function. However, previous research has revealed a large variability in creatinine measurements using different measuring methods. In this study the investigators aim to establish the degree of variability in different methods to measure creatinine in a heterogenous group of Caucasian people with and without renal function loss and the influence of this variability on renal function estimating equations and the 24-hour creatinine clearance.
Detailed Description: Apart from the 24-hour creatinine clearance, also formulas to estimate the glomerular filtration rate (GFR) are increasingly used to get an impression from renal function in recent years. Based on these renal function measurements, clinical decisions are made as well as drug dose adjustments. The use of reliable serum creatinine measurements is therefore important to get accurate renal function estimates. However, serum creatinine is one of the most variable routine laboratory tests.

The importance of calibration to a traceable reference measurement of serum creatinine has been stressed. However, this standardization does not correct for analytical non-specificity problems, which occurs in certain techniques to measure creatinine, leading to under- or overestimation of the true creatinine concentration.

The aim of this cross-sectional observational study is to examine the degree of variability between diverse methods to measure creatinine in plasma and urine in a heterogenous group of Caucasian people with and without renal function loss and the influence hereof on the 24-hour creatinine clearance and the Modification of Diet in Renal Disease study equation and the consequences for chronic kidney disease staging.