Viewing Study NCT02155959



Ignite Creation Date: 2024-05-06 @ 2:53 AM
Last Modification Date: 2024-10-26 @ 11:25 AM
Study NCT ID: NCT02155959
Status: COMPLETED
Last Update Posted: 2014-06-04
First Post: 2013-06-12

Brief Title: Performance of a Single-piece Toric Acrylic Intraocular Lens
Sponsor: Prim Prof Dr Oliver Findl MBA
Organization: Vienna Institute for Research in Ocular Surgery

Study Overview

Official Title: Rotational Stability of a Single-piece Toric Acrylic Intraocular Lens a Pilot Study
Status: COMPLETED
Status Verified Date: 2014-06
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Abstract Purpose To evaluate the visual performance and rotational stability of the Tecnis Toric one-piece IOL AMO USA during the first 3 post-operative months Design Prospective single center study Setting VIROS - Vienna Institute for Research in Ocular Surgery a Karl Landsteiner Institute Hanusch Hospitel Vienna Austria Methods In this prospective study patients with age-related cataract and corneal astigmatism of 10 to 30 D measured with the IOL-Master 500 Carl Zeiss Meditec AG Germany were included Pre-operatively rotating Scheimpflug scans Pentacam HR Oculus Germany were performed and the cornea was marked in the sitting position at the slit lamp Patients recieved a single-piece toric hydrophobic acrylic IOL Tecnis Toric AMO USA Immediately and 3 months after surgery retroillumination photographs were taken to assess the rotational stability of the IOL Additionally Autorefraction Topcon USA subjective refraction uncorrected and distance corrected visual acuity keratometry Scheimpflug and ocular wavefront WASCA Carl Zeiss Meditec AG Germany measurements were performed at the 3 months follow-up
Detailed Description: Whereas first designs of toric intraocular lenses toric IOLs in the early 1990s showed an IOL rotation of more than 30 in one fifth of the patients modern toric IOLs typically show a mean absolute rotation of 3 to 5 which would result in a loss of about 10 to 15 of the astigmatism reducing effect of the toric IOL

Rotational stability of a toric IOL depends on the interaction between the toric IOL and the posterior capsule whereas misalignment of the toric IOL defined in this study as the difference between the 3 months postoperatively measured axis of the toric IOL and the intended axis depends on several factors additionally to rotational stability Intraoperatively misalignment may happen due to cyclotorsion of the eye in the lying position or due to peribulbar anaesthesia and due to imprecision of the surgeon when positioning of the IOL relative to the intended meridian Both these imprecisions can be dealt with by pre-operative marking of the eye in the sitting position and diligence by the surgeon Postoperatively the IOL may rotate because it is undersized for the capsule bag or due to the capsule shrinkage that takes place during fibrotic contraction of the bag in the postoperative period Since most current IOLs are slightly oversized for the capsule bag the former is observed rarely and would be more likely in long eyes which tend to have a larger capsule bag diameter However capsule bag shrinkage is thought to induce rotation in IOLs with open-loop haptics due to the asymmetry of the haptic design Typical IOL haptic designs that improve rotational stability are either plate haptic IOLs or special Z-haptic shaped open-loop haptics that attempt to counteract the rotational effect of compression of the shrinking bag However both of these IOL designs are thought to have downsides The former seems to have an increased risk of posterior capsule opacification due to a less effective lens epithelial barrier effect of the optic edge and may also show more rotation in the bag immediately after surgery due to the shorter haptic overall length The latter IOL design such as the Z-haptic IOL is cumbersome to implant and may be prone to damage during implantation

Aim of this study was to evaluate the rotational stability of a novel single-piece hydrophobic acrylic toric IOL with a C-haptic design

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None