Viewing Study NCT01460459


Ignite Creation Date: 2025-12-24 @ 3:05 PM
Ignite Modification Date: 2025-12-31 @ 6:38 PM
Study NCT ID: NCT01460459
Status: UNKNOWN
Last Update Posted: 2011-10-26
First Post: 2011-10-19
Is Gene Therapy: True
Has Adverse Events: False

Brief Title: Self-monitoring of Blood Glucose in Insulin-treated Patients With Type 2 Diabetes
Sponsor: Medical Research Foundation, The Netherlands
Organization:

Study Overview

Official Title: Self-monitoring of Blood Glucose in Insulin-treated Patients With Type 2 Diabetes: a 9-month Randomised Controlled Trial
Status: UNKNOWN
Status Verified Date: 2011-10
Last Known Status: RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Primary Objective:

The objective of the study is to investigate the effect of a specific frequency of Self-monitoring of blood glucose (SMBG) on glycemic control and quality of life in patients with type 2 diabetes and who are in stable good glycemic control and using 1 insulin injection daily.

The research question is:

Does a less intensive frequency of SMBG in insulin-treated patients with type 2 diabetes, who are in stable good glycemic control, using 1 insulin injection daily, lead to a clinically relevant increase of HbA1c (an increase of 0.5%) and what is the effect on quality of life?

Secondary objectives:

The secondary objectives is to investigate the effect of a specific frequency of SMBG on the number of hypo and hyper glycaemia, number of extra diabetes-related contacts with the health care provider, and the diabetes medication.
Detailed Description: SUMMARY

Rationale:

Self-monitoring of blood glucose (SMBG) is an important tool in diabetes care to achieve and maintain good glycemic control. But how often 'should' the patient measure the capillary glucose concentration? There is no general agreement between professionals, and there is no evidence for a specific frequency and timing.

Objective:

The objective of the study is to investigate the effect of a specific frequency of SMBG on glycemic control and quality of life in patients with type 2 diabetes and who are in stable good glycemic control and using 1 insulin injection daily.

Study design:

An open Randomised Controlled Trial.

Study population:

Patients with insulin-treated diabetes type 2, \> 18 years of age, using 1 insulin injection daily, performing SMBG \> 1 year, HbA1c ≤ 58 mmol/mol (\< 7.5%) in the preceding 12 months, sufficient knowledge of the Dutch language, no hypo-unawareness, no serious co-morbidity

Intervention:

Patients are instructed to measure their blood glucose concentrations 4 times per day (pre-prandial and before bedtime) one day weekly in group A, one day per two weeks in group B and one day monthly in group C. Patients are asked to keep a diary with the readings and the probably extra measurements, including the reasons.

Main study parameters/endpoints:

The main study parameters are glycemic control and quality of life. A difference of \> 0.5% (\> 5.5 mmol/mol) in HbA1c is considered to be relevant. Quality of life is measured with 3 validated questionnaires.

Nature and extent of the burden and risks associated with participation, benefit and group relatedness:

Patients in this study are used to perform SMBG. During the study, they are asked to monitor their glucose concentrations in a controlled, specific frequency (different kind of usual care are compared). And they are asked to fill in 3 questionnaires in the beginning and at the end of the study. Extra HbA1c measurements can be necessary. No side effects are expected, but safety is incorporated through HbA1c measurements every 3 months and every 3 months the diary will be discussed in the scheduled visits. Furthermore, extra measurements are allowed when necessary.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: