Viewing Study NCT05091359


Ignite Creation Date: 2025-12-24 @ 3:04 PM
Ignite Modification Date: 2026-02-22 @ 4:14 PM
Study NCT ID: NCT05091359
Status: COMPLETED
Last Update Posted: 2021-10-25
First Post: 2021-09-03
Is NOT Gene Therapy: True
Has Adverse Events: False

Brief Title: Femur Transtrochanteric Fractures Treated With Dynamic Hip Screw and Calcium Sulfate Scaffold.
Sponsor: Hospital Regional Tlalnepantla
Organization:

Study Overview

Official Title: Unstable Proximal Femur Transtrochanteric Fractures Treated With Dynamic Hip Screw and ß -Tricalcium Phosphate/ Hemihydrated Calcium Sulfate Graft Scaffold
Status: COMPLETED
Status Verified Date: 2021-10
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: geneX
Brief Summary: This is a randomised prospective comparison study to evaluate the incidence of cut - out failure of the dynamic hip screw implant alone compared to the dynamic hip screw adding calcium sulfate through the cervical canal before placing the sliding screw for improvement of the implant stability integration and bone healing.
Detailed Description: Transtrochanteric fractures are a frequent entity, mainly in patients over 65 years old, with low bone density. Most of these fractures of the proximal femur are treated effectively with internal fixation with dynamic hip screw (DHS), nonetheless a conditional factor in the treatment success its in the fracture stability and in the osteoporosis severity.

There is controversy in the treatment decision in patients with osteoporosis and an unstable fracture added the risk of peri-prosthetic infection or increased bleeding during surgery means that the decision to place a DHS versus a prosthesis is debated.

This study represents the first comparison of closed reduction and internal fixation with DHS using calcium sulfate graft versus conventional DHS procedure.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: