Viewing Study NCT00143858



Ignite Creation Date: 2024-05-05 @ 11:49 AM
Last Modification Date: 2024-10-26 @ 9:14 AM
Study NCT ID: NCT00143858
Status: COMPLETED
Last Update Posted: 2009-08-11
First Post: 2005-08-31

Brief Title: Assessment of the Clinical Utility of Non Invasive Peripheral Signal Averaged Pulse Volume
Sponsor: University of Medicine and Dentistry of New Jersey
Organization: Rutgers The State University of New Jersey

Study Overview

Official Title: Assessment of the Clinical Utility of Non Invasive Peripheral Signal Averaged Pulse Volume
Status: COMPLETED
Status Verified Date: 2009-08
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: The purpose of this study is to determine the clinical usefulness of measuring the hearts pumping ability by measuring the Peripheral Pulse Volume PPV
Detailed Description: Peripheral Pulse Volume PPV is the change in the volume of a limb that occurs when blood passes through the limb The limb also acts as an electrical conductor whose electrical impedence changes with limb geometry and volume Each time the heart beats the volume of the limb segment changes and therefore its electrical impedence changes A plethysmograph can be used to measure volume changes of a part of the body by producing a plethysmographic waveform Selectively capturing a number of these plethysmographic wave forms with acceptable noise levels and averaging them using the EKG as a reference-timing signal generate a highly reproducible pulse volume signal Signal averaged pulse volume measurement will be obtained non-invasively from the lower extremities of patient volunteers A disposal non-occluding electrical monitoring strap will be applied to the calf of each patient Changes in the calfs sizevolume caused by changes in the patients cardiac output and calf blood flow will result in electrical impedance changes These changes will be recorded by an analog admittance plethysmograph attached to the lower extremity strap The analog plethysmograph is coupled to a digital computer for signal enhancement and measurement

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: None
Secondary IDs
Secondary ID Type Domain Link
investigator initiated None None None