Viewing Study NCT06692218


Ignite Creation Date: 2025-12-25 @ 5:03 AM
Ignite Modification Date: 2025-12-26 @ 4:06 AM
Study NCT ID: NCT06692218
Status: RECRUITING
Last Update Posted: 2024-11-18
First Post: 2024-09-26
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Leadless Pacemaker Implantation Positions and Its Relationship with Procedure Efficacy and Complication
Sponsor: Chinese University of Hong Kong
Organization:

Study Overview

Official Title: Leadless Pacemaker Implantation Positions and Its Relationship with Procedure Efficacy and Complication
Status: RECRUITING
Status Verified Date: 2024-09
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Leadless pacemakers (LP) are safe and effective alternatives to transvenous pacemakers in select patients. Advances in battery and electronics technology allow for the entire pacemaker system to be implanted into the right ventricle, bypassing many of the weaknesses of transvenous pacemakers. Traditionally leadless pacemakers have been implanted in the right ventricular (RV) septum to prevent cardiac perforation, and much emphasis is placed during implantation to ensure a septal implant. However, in Asians with smaller heart sizes, septal implantation may be unfeasible. Cases of RV free wall implant have been achieved without any complications. This study aims to examine patients previously implanted with LP and determine their final attachment location. If a substantial portion of complication-free patients had RV free wall implants, then it can be argued the additional effort to ensure a septal implant is unnecessary. Additionally, intraoperative data, such as the intracardiac electrogram, may contain parameters correlated with implant position. This study also aims to study this correlation to guide future implant procedures.

This is a prospective-retrospective cohort study. Patients who will implant leadless pacemakers or already implanted leadless pacemakers since 1 Jan 2015 will be recruited. After the implantation, patients will be invited back for a noncontrast ECG-gated CT heart. It will be timed at the end diastole and a 3D reconstruction will be performed. The attachment of the leadless pacemaker to the RV will be adjudicated from the CT. The patients' pre-operative laboratory tests, baseline demographics, medical history, LP electrical data and pre- and post-operative medication regiment will be collected retrospectively from their medical records in the Hospital Authority's Clinical Management System (CMS) and Clinical Data Analysis and Reporting System (CDARS).
Detailed Description: None

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: True
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: True
Is an FDA AA801 Violation?: