Viewing Study NCT01464918


Ignite Creation Date: 2025-12-25 @ 4:59 AM
Ignite Modification Date: 2025-12-26 @ 3:59 AM
Study NCT ID: NCT01464918
Status: UNKNOWN
Last Update Posted: 2011-11-04
First Post: 2011-10-30
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Safety and Efficacy of Using MASTER to Perform Endoscopic Submucosal Dissection in Human
Sponsor: National University Hospital, Singapore
Organization:

Study Overview

Official Title: Safety and Efficacy of Using MASTER, a Novel Robotics Enhanced Endosurgical System to Perform Endoscopic Submucosal Dissection in Human
Status: UNKNOWN
Status Verified Date: 2011-10
Last Known Status: NOT_YET_RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: This trial is to evaluate the safety and efficacy of using MASTER, a robotics enhanced endosurgical system to perform endoscopic submucosal dissection (ESD) of gastric/colon cancer in human.
Detailed Description: This trial is to evaluate the safety and efficacy of using MASTER, a novel robotics enhanced endosurgical system to perform endoscopic submucosal dissection (ESD) of gastric/colon cancer in human. The MASTER is a master-and-slave robotic system that is deployed through a standard dual-channel therapeutic endoscope. It introduces robotic control of endoscopic surgical tools and tasks through an ergonomic human-machine interface built around the original endoscopic paradigm. In doing so, it separates control of instrumental motion from that of endoscopic movement such that surgical tasks may be independently executed by a second operator via a human-machine interface. With it, endoscopically deployed instruments can be independently controlled, allowing thus bimanual coordination of effector instruments to facilitate actions such as retraction/exposure, traction/countertraction, approximation and dissection of tissue. Using the MASTER, operational dexterity is increased, thus making it easier for the operator to perform the ESD procedure as compared with using the conventional endoscope. This study will measure the ease of using the MASTER to perform the various surgical tasks involved in the ESD procedure, the time taken to perform the procedure, and record complications, if any, occurred during and after the procedure.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: None
Is a FDA Regulated Device?: None
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: