Brief Title: Influence of Different Toric Intraocular Lenses on IOL-capsular Complex
Sponsor: Wenzhou Medical University
Organization:

Study Overview

Official Title: Influence of Different Toric Intraocular Lenses on IOL-capsular Complex After Cataract Surgery
Status: UNKNOWN
Status Verified Date: 2022-04
Last Known Status: NOT_YET_RECRUITING
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Corneal astigmatism is refractive error that impairs uncorrected visual acuity. When patients undergo cataract surgery, implantation of toric IOL is deemed the most effective choice for correcting corneal astigmatism and reducing postoperative spectacle dependence. The IOL-capsular complex is formed after cataract surgery and intraocular lens (IOL) implantation. Early postoperative mechanical wrapping of the anterior and posterior capsules plays a significant role in preventing IOL decentration and tilt, as well as formation of the IOL-capsular complex which reduces the incidence of posterior cataract opacity. IOL decentration ≥ 0.4 mm or/and IOL tilt ≥7degree were considered clinically significant because of poor post-surgery visual quality especially for optical sophisticated IOLs such as toric IOLs. IOL instability could decrease the curative effect of toric IOL. There are numerous types of toric IOLs; however, AcrySof IQ and TECNIS toric IOL are most frequently used in the Ophthalmology Hospital of Wenzhou Medical University. AcrySof IQ IOL has some differences compared with TECNIS toric IOL. IQ has a modified L haptic design while TECNIS® toric IOL has a modified C haptic design. AcrySof IQ IOL has a discontinuous 360˚ posterior square edge while TECNIS toric IOL has a continuous 360˚ posterior square edge. The AcrySof IQ IOL cylinder power models include 1.00, 1.50, 2.25, 3.00, 3.75, 4.50, 5.25 and 6.00 D. The Tecnis IOL cylinder power models include 1.00, 1.50, 2.25, 3.00 and 4.00 D. Previous study pointed that patients with cataracts with corneal astigmatism achieved comparable improvement in visual acuity, astigmatism correction, CS(sensitive contrast), rotational stability and satisfaction, following AcrySof and TECNIS toric IOL implantation. However,some other studies found that the Acrysof toric IOL showed significantly greater rotational stability than the Tecnis toric IOL and the rate of surgical IOL repositioning was higher in eyes implanted with TECNIS than with AcrySof toric IOLs for astigmatic correction. Currently, there is no literature guidance to compare the results of cataract surgery combined various types of toric IOLs implantation in patients using CASIA2. The novel anterior segment optical coherence tomography (AS-OCT) device, CASIA2 can accurately evaluate the IOL capsule bending and the lens position after cataract surgery. Also, CASIA2 can be used to documented the dynamic changes of IOL-capsular complex after surgery.
Detailed Description: Corneal astigmatism is refractive error that impairs uncorrected visual acuity. When patients undergo cataract surgery, implantation of toric IOL is deemed the most effective choice for correcting corneal astigmatism and reducing postoperative spectacle dependence. The IOL-capsular complex is formed after cataract surgery and intraocular lens (IOL) implantation. Early postoperative mechanical wrapping of the anterior and posterior capsules plays a significant role in preventing IOL decentration and tilt, as well as formation of the IOL-capsular complex which reduces the incidence of posterior cataract opacity.

Although up to 2-3 degree tilt and a 0.2-0.3 mm decentration are common and clinically unnoticed for any design of IOL, larger extent of tilt and decentration has a negative impact on the optical performance. IOL decentration ≥ 0.4 mm or/and IOL tilt ≥7degree were considered clinically significant because of poor post-surgery visual quality especially for optical sophisticated IOLs such as toric IOLs. IOL instability could decrease the curative effect of toric IOL. There are numerous types of toric IOLs; however, AcrySof IQ and TECNIS toric IOL are most frequently used in the Ophthalmology Hospital of Wenzhou Medical University. AcrySof IQ IOL has some differences compared with TECNIS toric IOL. IQ has a modified L haptic design while TECNIS® toric IOL has a modified C haptic design. AcrySof IQ IOL has a discontinuous 360˚ posterior square edge while TECNIS toric IOL has a continuous 360˚ posterior square edge. The AcrySof IQ IOL cylinder power models include 1.00, 1.50, 2.25, 3.00, 3.75, 4.50, 5.25 and 6.00 D. The Tecnis IOL cylinder power models include 1.00, 1.50, 2.25, 3.00 and 4.00 D. Previous study pointed that patients with cataracts with corneal astigmatism achieved comparable improvement in visual acuity, astigmatism correction, CS(sensitive contrast), rotational stability and satisfaction, following AcrySof and TECNIS toric IOL implantation. However,some other studies found that the Acrysof toric IOL showed significantly greater rotational stability than the Tecnis toric IOL and the rate of surgical IOL repositioning was higher in eyes implanted with TECNIS than with AcrySof toric IOLs for astigmatic correction. Currently, there is no literature guidance to compare the results of cataract surgery combined various types of toric IOLs implantation in patients using CASIA2. The novel anterior segment optical coherence tomography (AS-OCT) device, CASIA2 can accurately evaluate the IOL capsule bending and the lens position after cataract surgery. Also, CASIA2 can be used to documented the dynamic changes of IOL-capsular complex after surgery.