Viewing Study NCT06731920


Ignite Creation Date: 2025-12-25 @ 4:27 AM
Ignite Modification Date: 2025-12-26 @ 3:30 AM
Study NCT ID: NCT06731920
Status: RECRUITING
Last Update Posted: 2024-12-13
First Post: 2024-12-11
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: USG CMBB DSA Study
Sponsor: Montreal General Hospital
Organization:

Study Overview

Official Title: The Incidence of Inadvertent Intravascular Injection During Ultrasound-guided Cervical Medial Branch Blocks: a Fluoroscopically Controlled Study
Status: RECRUITING
Status Verified Date: 2024-12
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Injections that freeze neck joints can be done using x-rays or ultrasound imaging, which as a newer way of guiding the needle to the right spot. This study will look at how often freezing liquid goes into a blood vessel during neck injections that freeze neck joints when ultrasound guidance is used to place the needle. When this happens, it can go undetected because it does not make the patient feel any different, however it could cause a test block to be falsely negative, leading to the wrong diagnosis. Based on previous studies, we think that this happens rarely, and the purpose of this study is to prove that conclusively
Detailed Description: Cervical medial branch blocks (CMBB) are commonly employed for the diagnosis and management of facet-related pain. The latter constitutes the most important cause of axial neck pain and has been implicated in 40% of all cases. In addition, the upper cervical joints can also cause cervicogenic headaches, an often-debilitating condition representing up to 20% of chronic headaches3. Well-defined pain referral patterns for each joint can help operators select the appropriate injection level. While fluoroscopy has long been the imaging standard for spinal procedures, ultrasound guidance (USG) is being increasingly adopted as an alternative and presents several advantages such as the ability to identify and avoid soft tissue structures such as blood vessels during needle insertion. From a clinical perspective, avoiding blood vessels and reducing the incidence of vascular breach can lessen the occurrence of intravascular injections that are associated with false negative diagnostic blocks. Indeed, a recent study examining the safety of USG CMBB reported a lower incidence of vascular breach than previous studies that had used fluoroscopic guidance. While these findings suggested a potential benefit associated with USG, further confirmatory studies employing digital subtraction angiography (DSA), the current imaging standard to detect intravascular spread, are required. We hypothesize that USG will be associated will a lower incidence of intravascular spread during primary needle placement than has been reported with fluoroscopic guidance.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: False
Is an FDA AA801 Violation?: