Viewing Study NCT04761120


Ignite Creation Date: 2025-12-25 @ 4:07 AM
Ignite Modification Date: 2025-12-26 @ 3:03 AM
Study NCT ID: NCT04761120
Status: RECRUITING
Last Update Posted: 2025-07-09
First Post: 2021-02-12
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Annuloplasty Rings and Band Post-Market Clinical Follow-Up Study
Sponsor: Abbott Medical Devices
Organization:

Study Overview

Official Title: Annuloplasty Rings and Band Post-Market Clinical Follow-Up (ARB-PMCF) Study
Status: RECRUITING
Status Verified Date: 2025-02
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: ARB-PMCF
Brief Summary: ARB-PMCF is a multicenter, observational study of the safety and performance of Abbott annuloplasty devices used in surgical repair of mitral and tricuspid valve regurgitation. The devices included in this study are the SJM™ Rigid Saddle Ring and SJM Séguin Annuloplasty Ring, indicated for mitral valve repair, and the SJM Tailor™ Annuloplasty Ring and SJM Tailor Annuloplasty Band, indicated for mitral or tricuspid repair. Participants will be enrolled prior to undergoing mitral or tricuspid valve repair surgery including an Abbott annuloplasty implant and will complete annual follow-up visits through five years from implant. The study is being conducted to meet post-market clinical follow-up requirements of the European Union Medical Device Directives.
Detailed Description: The ARB-PMCF Study has a prospective, multicenter, observational, parallel group design in which up to 550 subjects will be followed through five years from implant of an Abbott annuloplasty device, with or without concomitant procedures, in five treatment groups, including primary mitral disease repair (N=200) with the Rigid Saddle Ring, Séguin Ring or full Tailor Ring without cut zone removal; secondary mitral disease repair (N=200) with the Rigid Saddle Ring, Séguin Ring or full Tailor Ring; primary tricuspid disease repair with the full Tailor Ring (N=50); secondary tricuspid disease repair with the full Tailor Ring (N=50); and primary tricuspid disease repair with the Tailor Band or partial Tailor Ring with cut zone removed (N=50). Study enrollment will occur at up to 25 global centers with approximately half or more of all implanted subjects being from European sites. The study will enroll adult subjects expected to be implanted with an Abbott annuloplasty device within 90 days who meet all other eligibility requirements. Participants will complete annual in-clinic or telephone follow-up visits through five years from their annuloplasty implant. Data collected will include adverse events, cardiac medication usage, New York Heart Association functional classification (a measure of the severity of heart failure symptoms) and echocardiographic assessments of regurgitation through the repaired valve.

Study Oversight

Has Oversight DMC: False
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: True
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: True
Is an FDA AA801 Violation?: