Viewing Study NCT06278220


Ignite Creation Date: 2025-12-25 @ 4:06 AM
Ignite Modification Date: 2025-12-26 @ 3:03 AM
Study NCT ID: NCT06278220
Status: NOT_YET_RECRUITING
Last Update Posted: 2024-02-28
First Post: 2024-02-19
Is NOT Gene Therapy: False
Has Adverse Events: False

Brief Title: Scheimpflug Versus Placido-disc System in Evaluation of Corneal Higher-Order Aberrations
Sponsor: Assiut University
Organization:

Study Overview

Official Title: Scheimpflug Versus Placido-disc System in Evaluation of Corneal Higher-Order Aberrations Before and After LASIK
Status: NOT_YET_RECRUITING
Status Verified Date: 2024-02
Last Known Status: None
Delayed Posting: No
If Stopped, Why?: Not Stopped
Has Expanded Access: False
If Expanded Access, NCT#: N/A
Has Expanded Access, NCT# Status: N/A
Acronym: None
Brief Summary: Aim of work:

To assess the agreement between placido-based topographer (wavelight allegro topolyzer vario) and scheimpflug -based (Oculus Pentacam ) regard measuring corneal higher order aberrations before and after LASIK.
Detailed Description: Higher-order aberrations (HOAs) are small optical irregularities of the eye, which can have an impact on the quality of the retinal image. In contrast to lower order aberrations, these errors cannot be corrected with regular spectacles and most contact lenses. Additionally, HOAs are responsible for an array of visual symptoms including dysphotopsia, glare, as well as a reduction in contrast sensitivity. The cornea accounts for approximately 90% of ocular aberrations.Advances and breakthroughs in wavefront aberration measurement technology can help clinicians to better understand and manage corneal higher-order aberrations (HOAs), especially for the preoperative planning of corneal refractive surgery and cataract surgery.A recent study has shown that corneal HOAs can be a sensitive parameter to differentiate early keratoconus from normal eyes. Furthermore, corneal aberrations have been widely used to evaluate dry eye and orthokeratology.LASIK surgery is widely used in the correction of refractive errors It is well known that LASIK surgery induces high-order aberrations (HOA) .The main eye element involved in the generation of such aberrations is the first corneal surface. Currently, devices based on Placido-disc, Hartmann- Shack, ray tracing, or Scheimpflug are routinely used in clinical aberration measurement. Of which Pentacam is one of common instruments that can only measure corneal aberration (including anterior and posterior corneal surface) based on Scheimpflug technology. Also Allegro Topolyzer is a Placido-based topographer that can measure anterior corneal higher order aberrations (HOAs). A better understanding of the agreement of device measurements can provide clinicians with useful information for measuring, correcting, and monitoring aberrations around refractive and cataract surgery. Investigators , therefore, aimed to study the agreement between the two instruments in anterior corneal aberration measurement.

Study Oversight

Has Oversight DMC: None
Is a FDA Regulated Drug?: False
Is a FDA Regulated Device?: False
Is an Unapproved Device?: None
Is a PPSD?: None
Is a US Export?: None
Is an FDA AA801 Violation?: